Design Information
Installation on Flat Roofs
Collector supports with fixed angle of inclination
Collector supports with adjustable angle of inclination
6 6
Legend
A Footplates
B Rear support
C Collector support
Legend
A Front support slab
B Rear support slab
Vitosol 200-T, SP2A Technical Data
Refer to the Vitosol 200-T, SP2A Installation
Instructions for all mounting hardware
dimensions and detailed installation instructions.
When installing collectors, maintain the minimum
clearances towards the roof edge in accordance with
DIN 1055.
If the roof size necessitates a split array, ensure that
sections of the same size are created. The collectors can
be secured on any solid substructure or on concrete slabs.
When installing collectors on concrete slabs, secure them
with additional ballast against slippage, tipping and lifting.
Slippage is the movement of the collectors on the roof
surface due to wind, because of insufficient friction
between the roof surface and the collector fixing system.
Collectors can be secured by guy ropes or by being fixed
to other roof structures.
Vertical tube installation (elevated)
Angle of
30°
inclination
a
in.
95
(2413)
(mm)
Ballast and max. load on the substructure
Calculation in accordance with DIN 1055-4, 3/2005
and DIN 1055-5, 7/2005 or applicable local codes.
Two support slabs each, both A and B are required
for every collector.
Ballast weight requirements, as well as the calculation of
additional live loads (due to installation of solar collectors),
must be evaluated by a professional structural engineer.
Vitosol 200-T SP2A
Combination
x
2
2
1.51 m
/1.51 m
2
2
1.51 m
/3.03 m
2
2
3.03 m
/3.03 m
Note: For calculating z, see page 7.
Legend
A Front support slab
B Rear support slab
45°
60°
86.6
72.4
(2200)
(1838)
in.
y
(mm)
20/20
(505/505)
20/40
(505/1010)
40/40
(1010/1010)
in.
(mm)
23.5
(595)
33.5
(850)
43.5
(1100)