27. Remove the pump block assembly, block thrust
washer and spring from the input shaft and inspect
for unusual wear or damage. The pistons should fit
with very little side clearance in the block bores, but
must slide freely.
Steps 28 Through 32 Apply to
0650 Models Only
28. Remove the two internal hex head capscrews retain-
ing the jackshaft to the housing with a 5 mm hex
wrench and remove the jack shaft/pinion gear assembly
from the housing.
29. Inspect the jackshaft running surface for excessive
wear or damage. The jackshaft should be 0.4986" to
0.4996".
30. Inspect the pinion gear bore for excessive wear or
damage. The bore should be 0.5014" to 0.5024".
31. Inspect the pinion gear teeth for excessive wear or
damage.
32. If excessive wear or damage was found, the com-
plete assembly should be replaced.
11 Transmission Teardown
Figure 15. Remove Pump Block Assembly
Figure 16. Remove Jackshaft / Pinion Gear Assy.
Figure 17. Jack Shaft/Pinion Gear Components