Operational Features - Toyotomi TAD-T35 Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

SUMMARY
The idea behind the unit is to provide a localized supply of cool air.
The unit will greatly enhance your personal comfort whether at a
work station or even in your favorite chair.
Four (4) casters enable you to move the unit easily from room to
room. It cools and dries the air at the same time so that you can
stay comfortable even when it's humid or rainy outside.
Also your furnishings and fabrics are kept in good condition when
it's used as dehumidifier.
Conventional air conditioners use large quantities of energy to cool
an entire room, including walls and furniture. This unit creates a
zone of cool and dry air only where it is needed. It does not waste
energy cooling the surroundings.
It's easy to operate. The built-in timer allows from 1 to 12 hours of
operation, which will automatically turn the unit on and off. This is
especially convenient at bedtime.
Venting is not required. However, if the unit is to be used exclu-
sively in one space, the cooling efficiency will be enhanced by us-
ing the venting kit accessory, which is included with the unit.

OPERATIONAL FEATURES

1.
COOLING OPERATION:
Normally, cool air is directed out the front louvers by the circu-
lation fan which has three (3) stages of fan speed.
2.
AUTOMATIC OPERATION:
Once the desired function has been set, it is memorized as
long as it remains connected to the wall outlet. In the event of
a power failure, the desired function must be re-entered when
power is restored.
3.
THERMO CONTROL:
The compressor will automatically shift to ON or OFF to main-
tain the desired temperature.
4.
TIMER OPERATION:
The unit will turn on and off after the designated period of time
(1, 2, 3, ...24 hours).
5.
AUTOMATIC SHUT-OFF MECHANISM WHEN THE DRAIN
TANK IS FULL:
Condensed water may accumulate in the unit. If the internal
tank becomes full, the Warning Light
omatically shut-off. It is always required to press the power -
button twice to resume operation after the condence water is
removed from the tank.
6.
AIR FILTER:
A pre-filter protects the unit from dust.
1. DESCRIPTION
Fig. A
FRONT
A1
Air outlet
A2
Front panel
A3
Operation panel
A4
Remote control
A5
Carrying handle
A6
Indication panel
A7
Caster
Fig. B
REAR
B1
Air intake (Evaporator)
B2
Exhaust outlet
B3
Air intake (Condenser)
B4
Power supply cord
B5
Power plug
B6
Drain water outlet
B7
Air intake grille (Pre-filter)
Fig. C
OPERATION PANEL
C1
Power button
C2
Mode button
C3
Fan speed button
C4
Timer button
C5
Adjust buttons
C6
Warning lamp (Tank full)
C7
Cool mode lamp
C8
Dry mode lamp
C9
Fan mode lamp
C10
Room/Set temp lamp
C11
Timer set lamp
C12
Fan speed lamp
2. SAFETY TIPS
IMPORTANT
will flash and aut-
1
Fig. I
EXHAUST DUCT SET
I1
Duct hose adapter nozzle
I2
Duct hose grille
I3
Exhaust hose
INTAKE DUCT SET
I4
Duct hose adapter nozzle
I5
Duct hose grille
I6
Exhaust hose
Fig. J
WINDOW PANEL KIT
J1
Window panel
J2
Window panel extension (2 pcs.)
J3
Cover (2 pcs.)
J4
Screw and Wing nut (2 pcs.)
Read instructions carefully before operation.
The unit should be operated when the room temperature is
between 61°F (16°C) to 95°F (35°C). If the room temperature is
below 61°F (16°C), ice may form on the coils. If the room tem -
perature is above 95°F (35°C), the compressor will automati-
cally shut off to protect itself.
ALWAYS, wait 3 min. to restart after turning unit off.
WARNING
NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.
Keep children away from unit. Children are particularly liable to
this danger. The inside fan is running at high speed. Covering
them may deteriorate air conditioner performance or cause it
to become inoperative.
NEVER insert objects of any kind into the air intake or air out-
let.
DO NOT unplug if your hands are wet. An electrical shock may
occur.
DO NOT operate in a wet location.
ALWAYS plug into 115 V, 60 Hz, single phase electrical outlet.
Be sure the power plug fits the receptacle securely.
DO NOT run power cord under carpets, rugs, or floor mats of
any kind.
DO NOT attempt to shorten or alter power cord in any way.
DO NOT apply any excessive force or pressure to the power
supply cord.
Make sure that the plug is free of dust.
DO NOT use an extension cord.
DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.
If there is a fear of lightning, stop the unit and disconnect the
power supply cord.
DO NOT touch the evaporator, condenser and pipes.
DO NOT operate with filter removed.
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
CAUTION
Keep unit more than 20 in. (50 cm) away from any objects or
wall. (Fig. D)
If the unit is operated in Cooling mode in an area of very high
moisture, the top plate and the rear plate may get covered
with a mist. Wipe off any mist before it has a chance to get on
the floor or rug.
Remove drain water before moving unit.
To minimize corrosion, DO NOT use in damp, salty air area.
DO NOT operate in direct sunlight.
DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.
DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.
DO NOT ride or place the objects on the unit.
DO NOT turn the unit on its side or upside down.
DO NOT remove the rubber cap cover and rubber cap of wa-
ter drainage outlet except in continuous drainage mode to
avoid water leakage.
ENGLISH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents