Operational Features; Safety Tips - Toyotomi TAD-35E Operating Manual

Mobile air conditioner
Table of Contents

Advertisement

SUMMARY
The idea behind the unit is to provide a localized supply of cool air. The
unit will greatly enhance your personal comfort whether at a work sta-
tion or even in your favorite chair.
Four (4) casters enable you to move the unit easily from room to room.
It cools and dries the air at the same time so that you can stay comfort-
able even when it's humid or rainy outside. Also your furnishings and
fabrics are kept in good condition when it's used as dehumidifier.
Conventional air conditioners use large quantities of energy to cool an
entire room, including walls and furniture. This unit creates a zone of
cool and dry air only where it is needed. It does not waste energy cool-
ing the surroundings.
It's easy to operate. The built-in timer allows from 1 to 12 hours of op-
eration, which will automatically turn the unit on and off. This is espe-
cially convenient at bedtime.
Venting is not required. However, if the unit is to be used exclusively in
one space, the cooling efficiency will be enhanced by using the venting
kit accessory, which is included with the unit.

OPERATIONAL FEATURES

1.
COOLING OPERATION:
Normally, cool air is directed out the front louvers by the circu-
lation fan which has three (3) stages of fan speed.
2.
AUTOMATIC OPERATION:
Once the desired function has been set, it is memorized as
long as it remains connected to the wall outlet. In the event of
a power failure, the desired function must be re-entered when
power is restored.
3.
THERMO CONTROL:
The compressor will automatically shift to ON or OFF to main-
tain the desired temperature.
4.
TIMER OPERATION:
The unit will turn on and off after the designated period of time
(1, 2, 3, ... 12 hours).
5.
AUTOMATIC SHUT-OFF MECHANISM WHEN THE DRAIN
TANK IS FULL:
When the drain tank is full, the unit will be automatically shut
off. The warning lamp will light. It is always required to press
the power button twice to resume operation after the con-
densed water is removed from the tank.
6.
AIR FILTER:
A pre-filter protects the unit from dust.
1. DESCRIPTION
Fig. A
FRONT
A1
Air outlet
A2
Vertical louver
A3
Front panel
A4
Operation panel
A5
Carrying handle
A6
Horizontal louver
A7
Caster
Fig. B
REAR
B1
Air intake (Evaporator)
B2
Exhaust outlet
B3
Air intake (Condenser)
B4
Power supply cord
B5
Power plug
B6
Drain water outlet
B7
Water outlet drain for continuous drain operation
(Dehumidify mode only)
B8
Air intake grille (Pre-filter)
Fig C
OPERATION PANEL
C1
Power button
C2
Mode button
C3
Fan speed button
C4
Timer button
C5
Adjust buttons
C6
Warning lamp (Tank full)
C7
Cool mode lamp (green)
C8
Dry mode lamp (red)
C9
Fan mode lamp (orange)
C10 High air flow lamp
C11 Med air flow lamp
C12 Low air flow lamp
C13 Room temp lamp
C14 Set temp lamp
C15 Timer set lamp
C16 Digital indicator
Fig. H
EXHAUST DUCT SET
H1
Exhaust duct hose adapter nozzle (2 pcs.)
H2
Exhaust nozzle
H3
Exhaust duct hose

2. SAFETY TIPS

IMPORTANT
• Read instructions carefully before operation.
• The unit should be operated when the room temperature is
between 18˚C to 35˚C. If the room temperature is below 18˚C,
ice may form on the coils. If the room temperature is above
35˚C, the compressor will automatically shut off to protect it-
self.
• ALWAYS, wait 3 min. to restart after turning unit off.
WARNING
• NEVER expose infants, handicapped persons, or senior per-
sons directly to the airflow. Adjust the airflow direction.
• Keep children away from the unit. Children are particularly li-
able to this danger. The inside fan is running at high speed.
Covering them may deteriorate air conditioner performance or
cause it to become inoperative.
• NEVER insert objects of any kind into the air intake or air out-
let.
• DO NOT unplug if your hands are wet. An electrical shock may
occur.
• DO NOT operate in a wet location.
• ALWAYS plug into 220~240V, 50Hz, single phase electrical
outlet.
• Be sure the power plug fits the receptacle securely.
• DO NOT run power cord under carpets, rugs, or floor mats of
any kind.
• DO NOT attempt to shorten or alter power cord in any way.
• DO NOT apply any excessive force or pressure to the power
supply cord.
• Make sure that the plug is free of dust.
• DO NOT use an extension cord.
• DO NOT turn on and off by inserting or removing the power
plug which may cause electric shock or fire.
• If there is a fear of lightning, stop the unit and disconnect the
power supply cord.
• DO NOT touch the evaporator, condenser and pipes.
• DO NOT operate with filter removed.
CAUTION
• Keep unit more than 50 cm (20 in) away from any objects or
wall. (Fig. G)
• If the unit is operated in COOL mode in an area of very high
moisture, the top plate and the rear plate may get covered
with a mist. Wipe off any mist before it has a chance to get on
the floor or rug.
• Remove drain water before moving unit.
• To minimize corrosion, DO NOT use in damp, salty air area.
• DO NOT operate in direct sunlight.
• DO NOT use for such particular purpose as preservation of
foodstuff, animals, plants, precision appliances, arts and med-
icine.
• DO NOT place an animal, plants or combustion equipment in
a place which is subjected to the direct air flow of the unit.
• DO NOT ride or place the objects on the unit.
• DO NOT turn the unit on its side or upside down.
1
ENGLISH

Advertisement

Table of Contents
loading

Table of Contents