Toshiba H9 Quick Start Manual page 39

Adjustable speed drive
Table of Contents

Advertisement

DBR Load — Displays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.
Feedback (inst) — Provides a status of the Real Time Feedback in Hz.
Feedback (1 second) — Provides a status of the 1-Second Averaging feedback in Hz.
Torque — Displays the Output Torque as a percentage of the rated capacity of the H9 ASD.
Torque Reference — Displays the Torque Reference as a percentage.
Torque Current — Displays the torque-producing current value.
Excitation Current — Displays the current value required to produce the excitation field.
PID Feedback — Provides a status of the PID Real Time Feedback in Hz.
Input Power — Displays the Input Power in Kilowatts (kW).
Output Power — Displays the Output Power in Kilowatts (kW).
Pattern Group Number — Displays the active Pattern Run Group Number.
Pattern Group Cycle — Displays the cycle number of the active Pattern Run Group.
Pattern Group Preset — Displays the active Preset Speed being run of the active Pattern Run
Group.
Pattern Time — Displays the remaining time for the active Pattern Run Group.
RR — Displays the RR input value as a percentage of the full range of the RR value (potentiometer
input).
V/I — Displays the V/I input setting as a percentage of the full range of the V/I value.
Note:
The isolated V/I input terminal may receive Current or Voltage to control the
output speed or the output torque. The input signal type must be selected at SW301
on the Terminal Board.
The V input setting of SW301 is used for the 0 – 10 VDC analog input signal and
the I input setting of SW301 is used for the 0 – 20 mA analog input signal. Either
may be used as a frequency or torque command source. See parameter F201 for
more information on the setup of this terminal.
RX — Displays the RX input setting as a percentage of the full range of the RX value (-10 to
+10 VDC input).
RX2 Option (AI1) — Displays the RX2 input setting as a percentage of the full range of the RX2
value.
Note:
The RX2 function is available on the Expansion IO Card Option 1 option board
(P/N ETB003Z) only.
Trip Code — Displays None if there are no errors, or displays one of the associated Fault Codes
listed in the H9 ASD Installation and Operation Manual if there is an active Fault (e.g., E =
Emergency Off).
32
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
H9 ASD Quick Start Guide

Advertisement

Table of Contents
loading

Table of Contents