Installation - Empire Comfort Systems DVL25FP32 Series Installation Instructions And Owner's Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Optional Blower Accessory
The Loft fireplace may be equipped with an optional FBB8 blower
accessory. See page 38.
The blower accessory may be installed at any time before or af-
ter installation of the fireplace providing that the junction box has
been properly pre-wired and secured to the right hand side of the
fireplace outer wrap. See Figures 10, 43 and 44.
Caution: Wiring must be performed by a qualified electrician.
NOTE: For shipping purposes, the junction box is installed on the
inside of the outer fireplace wrap. It is secured with (2) screws on
the side of the fireplace. Once removed from the side of the fire-
place, wiring to the junction box and receptacle can be performed.
Re-install the junction box assembly to the side of the fireplace so
that the receptacle faces inward. See page 11, Figure 10.
vERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL
(REqUIRES 24" vERTICAL RISE)
90º ELBOW
"B"
"A"
"B"
11 1/4" to 12 3/4"
6"
(286 mm to 324 mm)
14 1/4" to 15 3/4"
9"
(362 mm to 400 mm)
17 1/4" to 18 3/4"
12"
(438 mm to 476 mm)
Figure 13
30369-18-0619
INSTALLATION (CONT'D)
"A"
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
"C"
"C"
4 3/4" to 6 1/4"
(121 mm to 159 mm)
7 3/4" to 9 1/4"
(197 mm to 235 mm)
10 3/4" to 12 1/4"
(273 mm to 311 mm)
CORNER INSTALLATION vERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
(REqUIRES 24" vERTICAL RISE)
"A"
"B"
"D"
Dim.
DvL25FP
A
37-13/16"
B
26-3/4"
C
14-1/16"
53-1/2"
D
Figure 14
WALL FIRESTOP/
THIMBLE
6" (152mm)
MINIMUM
"C"
VENT
CAP
1" (25.4mm)
MINIMUM
9" (229mm)
MINIMUM
DvL33FP
42-11/16"
30-3/16"
15-5/16"
60-3/8"
Page 13