Appendix 2 – Refrigerant Piping Tables (English Units)
Table 4: Copper Tube Data
Wall
Diameter
Nominal
Type
Diameter
(inches)
K
0.049
1/2
L
0.035
K
0.049
5/8
L
0.040
K
0.049
3/4
L
0.042
K
0.065
7/8
L
0.045
K
0.065
1-1/8
L
0.050
K
0.065
1-3/8
L
0.055
K
0.072
1-5/8
L
0.060
K
0.083
2-1/8
L
0.070
K
0.095
2-5/8
L
0.080
K
0.109
3-1/8
L
0.090
K
0.120
3-5/8
L
0.100
K
0.134
4-1/8
L
0.110
K
0.160
5-1/8
L
0.125
K
0.192
6-1/8
L
0.140
K
0.271
8-1/8
L
0.200
ASHRAE Handbook HVAC Systems And Equipment, Chapter 41, 2004.
© American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., www.ashrae.org.
AG 31-011 • REFRIGERANT PIPING DESIGN
Diameter
Surface Area
Outside D,
Inside D
Outside
(in .)
(in .)
(ft²/ft)
0.500
0.402
0.131
0.500
0.430
0.131
0.625
0.527
0.164
0.625
0.545
0.164
0.750
0.652
0.196
0.750
0.666
0.196
0.875
0.745
0.229
0.875
0.785
0.229
1.125
0.995
0.295
1.125
1.025
0.295
1.375
1.245
0.360
1.375
1.265
0.360
1.625
1.481
0.425
1.625
1.505
0.425
2.125
1.959
0.556
2.125
1.985
0.556
2.625
2.435
0.687
2.625
2.465
0.687
3.125
2.907
0.818
3.125
2.945
0.818
3.625
3.385
0.949
3.625
3.425
0.949
4.125
3.857
1.080
4.125
3.905
1.080
5.125
4.805
1.342
5.125
4.875
1.342
6.125
5.741
1.603
6.125
5.845
1.603
8.125
7.583
2.127
8.125
7.725
2.127
Cross Section
Inside (ft²/
Metal Area
Flow Area
ft)
(in²)
(in²)
0.105
0.069
0.127
0.113
0.051
0.145
0.138
0.089
0.218
0.143
0.074
0.233
0.171
0.108
0.334
0.174
0.093
0.348
0.195
0.165
0.436
0.206
0.117
0.484
0.260
0.216
0.778
0.268
0.169
0.825
0.326
0.268
1.217
0.331
0.228
1.257
0.388
0.351
1.723
0.394
0.295
1.779
0.513
0.532
3.014
0.520
0.452
3.095
0.637
0.775
4.657
0.637
0.640
4.772
0.761
1.033
6.637
0.771
0.858
6.812
0.886
1.321
8.999
0.897
1.107
9.213
1.010
1.680
11.684
1.022
1.387
11.977
1.258
2.496
18.133
1.276
1.963
18.665
1.503
3.579
25.886
1.530
2.632
26.832
1.985
6.687
45.162
2.022
4.979
46.869
40
Working Pressure
Weight
ASTM B88 to 250°F
Annealed
Drawn
Tube (lb/ft)
(PSIG)
(PSIG)
0.269
894
1676
0.198
638
1197
0.344
715
1341
0.285
584
1094
0.418
596
1117
0.362
511
958
0.641
677
1270
0.455
469
879
0.839
527
988
0.654
405
760
1.037
431
808
0.884
365
684
1.361
404
758
1.143
337
631
2.063
356
668
1.751
300
573
2.926
330
619
2.479
278
521
4.002
318
596
3.325
263
492
5.120
302
566
4.291
252
472
6.510
296
555
5.377
243
456
9.674
285
534
7.609
222
417
13.867
286
536
10.200
208
391
25.911
304
570
19.295
224
421
www.DaikinApplied.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-410aR-407cR-134a