Honda GP160H Manual page 44

Table of Contents

Advertisement

dummyhead
dummyhead
ENGINE DOES NOT STOP WHEN
ENGINE STOP SWITCH IS TURNED OFF
Check the engine stop switch (page 10-3).
Normal
Check the wire harness connecting the engine
stop switch and the ignition coil for open circuit.
Continuity
Check the ignition coil primary side (page 8-7).
Replace the ignition coil if abnormalities are
found, and recheck.
ENGINE DOES NOT STOP WHEN ENGINE OIL
LEVEL IS LOW (WITH OIL LEVEL SWITCH AND
OIL ALERT UNIT TYPE ONLY)
Check the oil level switch (page 10-3).
Normal
Check the oil alert unit (page 10-4).
Normal
Check the wire harness connecting the oil level
switch and ignition coil for open circuit.
Continuity
Check the ignition coil primary side (page 8-7).
Replace the ignition coil if abnormalities are
found, and recheck.
Replace the engine stop switch (page 10-2).
Abnormal
Replace the engine wire harness.
No continuity
Replace the oil level switch (page 10-2).
Abnormal
Replace the oil alert unit (page 10-3).
Abnormal
Replace the engine wire harness.
No continuity
TROUBLESHOOTING
4-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp200h

Table of Contents