BYD Battery-Box HV
QUICK REFERENCE GUIDE
Valid for Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5
Target Group
Skilled personnel recognized
This manual and the tasks and procedures described herein are intended for use by skilled workers only.
A skilled worker is defined as a trained and qualified electrician or installer who has all of the following skills and expenence:
• Knowledge of the functional principles and operation of on-grid systems.
• Knowledge of the dangers and risks associated with installing and using electrical devices and acceptable mitigation methods.
• Knowledge of the installation of electrical devices.
• Knowledge of and adherence to this manual and all safety precautions and best oractices.
• In order to ensure the normal operation of Battery-Box, please be sure to update the firmware to the latest version and finish the configuration on
Battery-Box webpage in accordance with this document.
• The system switch must be off before installing.
• Please make sure the system switch is off in case of the system not working, and it would be better to repair it again within one week, avoiding
overdischarge or other problems happen.
• Please do not stack up batteries without protective package when storing or handling batteries, unless in the case of installation.
• Please read the quick reference guide and installation manual carefully before installation.
• Please download and view the installation manual on this website:
Installation environment requirements
Max.
+50℃
YES
NO
Direct sunlight
Allen key
Tools
Packing list
Wall-mounted ×1
M4×3
Overall structure
Please refer to the BYD minimum Configuration List and to the inverter information
regarding the possible module configuration (n) with different Inverters.
n=5, 6.4KWh
n=4, 5.1KWh
Min.
-10℃
YES
NO
Direct rain fall
Wire clamp
Phillips screwdriver
Packing of BCU+BASE
Expansion bolt M6×2
n=6, 7.7KWh
www.eft-systems.de(Support->Downloads)
YES
Snow
NO
accumulation
levelling instrument open-ended wrench
Sealing plug black ×3
Sealing plug white ×3
n=8, 10.2KWh
n=7, 9.0KWh
RH.
+5%~+95%
NO
Flammable material or
gas near the installation
NO
Flammable wall
churn drill
Packing of B-Plus H 1.28
Sealing plug white ×2
n=9, 11.5KWh
BCU
B-Plus H 1.28
Base
V 5

Advertisement

loading

Summary of Contents for BYD Battery-Box HV

  • Page 1 Sealing plug black ×3 Sealing plug white ×3 Overall structure n=9, 11.5KWh Please refer to the BYD minimum Configuration List and to the inverter information n=8, 10.2KWh regarding the possible module configuration (n) with different Inverters. n=7, 9.0KWh n=6, 7.7KWh n=5, 6.4KWh...
  • Page 2 Separate base Unpack Balance Install wall-mounted and BCU BCU + Base B-Plus H 1.28 D=52mm~60mm 635 755 875 995 1115 Open the cover of BCU Install Battery and BCU Lock sealing plug 1.Before installing BCU, make sure the system switch is switch off. 2.For better installation, for each battery installed, lock it tightly and reload the next battery.
  • Page 3 Setting method reference computer system setting method ④ BYDxxx Username installer Password byd@12345 cancel login Setup system information Battery-Box HV Time and Date Hour : Min : Day : Month : Year : Privacy Policy Next STEP 1 STEP 2 FINISH &...
  • Page 4 13a. SMA Sunny Boy storage 2.5 / 3.7 / 5.0 / 6.0 Use a twisted-pair wire for CAN_H and CAN_L (PIN 6 and 8). This is important for the stability of the CAN Battery-Box Battery-Box Choose any one Sunny Boy Storage Set Battery parameters in the SMA inverter: SMA SBS Parameter...
  • Page 5 13C. KOSTAL PLENTICORE plus B-Box KOSTAL PLENTICORE PLUS 1 2 3 4 5 6 13d. Goodwe ET Inverter ① Cut the BMS cable of the Goodwe ET (according to Goodwe Manual). Goodwe ET Goodwe ② Connect the blue PIN to terminal block position 6 and the white-blue PIN to terminal block position 8, according to the picture.
  • Page 6 13e. Fronius Symo Hybrid Please refer to the inverter installation manual for detailed wiring. 1. When connecting the meter in the second connection mode, the jumper cap above the JP2 in the BCU PCBA must be unplugged. If not unplugged, it is possible that the Battery-Box and inverter will not be able to communicate properly.
  • Page 7: Battery-Box

    13F. Ingeteam Ingecon Sun Storage 3TL and 6TL Ingeteam Battery-Box Ingeteam CAN IN-H Battery-Box CAN IN-L Blue Ethernet cable without the RJ45 terminals white-blue Battery-Box HIGH VOLTAGE EXTENSION Without charger 15c. Charge or discharge the original battery system so SOC=30%-40% that its SOC becomes 30% to 40%, and add another battery module.
  • Page 8 This manual is a shortened assistance for the installation of the original Anleitung der Battery-Box, erhältlich auf www.eft-systems.de Battery-Box HV and does not replace the original manual, which can be Installation darf nur von Fachleuten durchgeführt werden. Achtung found on www.eft-systems.de The installation must be carried out by a Hochvoltspeicher! Bei unsachgemäßer Handhabung kann Gefahr für Leib...