Reference Information (SYSTEM ATTACH)
pa2:
Bit
Content
Description
7
B'l'
Always I
6
B'O'
Always 0
5
Forcing Insert Character
B'O'
Disabled·
B'l'
Enabled
4
B'O'
Reserved
3
Operator Initiated Transparent Mode
B'O'
Enabled·
B'l'
Disabled
2
New Line
B'O'
Generates a LF character when the Return key is
pressed (when the Return Key parameter is New Line
or in an unformatted page)
B'l'
Generates a CR character when
~e
Return key is
pressed·
(when the Return Key parameter is New Line
or in an unformatted page)
I
B'O'
Reserved
op:
The operation-specifier parameter op can
be
added. This parameter must be
placed at the end of the parameter field. If this parameter is specified, bits 7 and
6 of the parameter pa2 must
be
B'O' and B'l', respectively. For more
information, refer to "Operation Specifier" in
IBM
3151
ASCII Display Station
Reference Manual.