2-way, ansi class 150 butterfly valve reinforced tefl on seat, 316 stainless disc (28 pages)
Summary of Contents for Belimo B2100VB-024
Page 1
V BALL CONTROL VALVES High Performance for Aggressive Applications • High performance ANSI Class 150 and 300 carbon steel bodies ideal for aggressive applications. • Fluid temperature up to 380°F is ideal for chilled, hot water or steam service. • Fitted with rotary actuators for easy fi eld assembly and installation.
Page 2
Part number for tagging: NC/FC = Normally Closed/Fail Closed X-XXXXX Create custom MFT 99981-00101 confi guration in the fi eld Refers to valve ports A to AB. with MFT-actuator PC-Tool software : B2100VB-024+AMX24-MFT-X1 Complete Ordering Example : +NO Confi guration : +A01 Programming...
Page 3
2-way Non-Spring Spring Electronic Inches 2-way NPT [mm] Flanged Return Return Fail-Safe B2100VB-024 1½ B2150VB-055 B2200VB-077 Equal Percentage B6300VB-207 Characteristic B6400VB-350 B6600VB-507 Mode of Operation The control valve is operated by an electronic actuator that responds to a standard voltage for on/off control, NOTE: Industrial ball valves have serviceable components.
Page 4
Set-Up V Ball Valves SET-UP - Specify Upon Ordering 2-WAY VALVE AMB24-3-X1, GMB24-3-X1, Power to pin 2 will drive valve CW. SY... Power to pin 3 will drive valve CCW. The above will fuction when the directional switch is in the ”1” position to reverse, select the ”0”...
General Information / Typical Installation V Ball Valves FLOW PATTERN PIPING DIAGRAMS Water Application Steam Application 2-way Valve Piping Diagram 2-way Valve Piping Diagram PIPING/MOUNTING ORIENTATION Assembly can be mounted horizontally or vertically for water applications. For steam applications the valve can be mounted vertically but if mounted horizontally the valve must be 90°...
Mounting and Installation Instructions V Ball Valves Mounting Installation The valves can be mounted in any position, except stem below horizontal. Inspect shipping package, valve, linkage, and actuator for physical damage. If shipping damage has occurred notify appropriate carrier. Do not install. Install valve with the proper ports as inlets and outlets.
See wiring diagram. Wire Type and Wire Installation Tips For most installations, 18 or 16 Ga. cable works well with Belimo actuators. Use code-approved wire nuts, terminal strips or solderless connectors where wires are joined. It is good practice to run control wires unspliced from the actuator to the controller.
Where Available on NFC Labeled Actuators Only actuator is not powered. Available through Google Play MFT-P Belimo MFT confi guration software (V3.X), includes PC-Tool software (interface cables [ZTH US] not included). Available for all MFT Actuators Physical copy of software. Free download also available at www.belimo.us/americas/mft.html...