Four-ball tester

Advertisement

2.3.3 Status
Speedometer
Motor load
Progress display
Scaling factor
2.3.3.1 Status
The "Status" window displays the current values while the motor is running. The torque
is displayed in % of the maximum torque of the motor.
When you click the start button, the control unit automatically jumps to that window.
You cannot select the "Option" and "Measurement" windows while the motor is
running.
The lower diagram shows the progress of the measurand selected under "Option".
The progress display is automatically scaled to the duration of the measurement.
When you click "Speedometer" on the Touchdisplay, a window will open that allows you
to change the rotational speed while the machine is in operation.
Attention!
After completion of a test or abort a test, a restart is possible only after pressing the
"Reset" button.
2.4 Jockey weight adjustment
You can set the load by moving the jockey weight on the balance scale bar (pos. 24).
Jockey weights are available in 1, 2, 2.5, 5, 7 or 10kg.
Make sure that the indexing lever (pos. 31) points away from the housing.
Use the indexing lever to lock the load required.
Warning:
Before you mount the 10kg jockey weight, you must remove the "cylinder screw"
(pos. 91). For safety reasons, put the screw back after you have mounted the weight.
16