Page 1
AUTOMATIC ADVANCED BLOOD PRESSURE MONITOR WITH COMPUTER-LINK TECHNOLOGY 2 USERS INSTRUCTION Recommended by Recommandé par the Canadian la Société Hypertension Society canadienne d’hypertension MANUAL BHS A/A – BHS Protocol...
About MAM Technology (optional) 1.6A Why Use MAM? 1.6B Key Advantages 1.6C Medical Benefits 1.6D Measurement Sequence Getting Started About the BD850 About the LCD Screen Inserting the Batteries Selecting the Right Cuff Storing the Cuff Using the Device Setting the Time, Date and User...
Page 3
Error Messages / Malfunctions Care and Maintenance Lifetime Guarantee Reference to Standards Technical Specifications Contact for Support...
1.1 Features The BD850 is a fully automatic, digital, blood pressure measuring device with a unique fuzzy logic technology as well as patented MAM and PAD technologies. It can store up to 99 blood pressure readings for each of the two users.
• Try to record your blood pressure regularly at the same time of the day and under the same conditions. This will help your physician detect any extreme variations in your blood pressure and thus treat you accordingly. • Morning Hypertension ( > 135 / 85 mm Hg): Recently, several studies have identified elevated cardiovascular risks (heart failure, stroke, angina) associated with “morning hypertension”.
• If the unit has been stored at very low or freezing temperatures, allow to reach room temperature before using it. • Do not store the unit in direct sunlight, high humidity, or in places with a lot of dust. •...
Your blood pressure also increases and decreases under the following circumstances Blood pressure is higher than normal: • when you are excited, nervous, or tense • while taking a bath • during and after exercise or strenuous physical activity • when it is cold •...
flow chart of the MAM Sequence Measurement 1 15 Second Rest Measurement 2 Data Analysis Measurement 3 15 Second Rest Result Diagram 1 2. Getting Started 2.1 About the BD850 This section describes the various components of the BD850.
Item Function 1. LCD Screen Your recorded blood pressure, heart rate and time are displayed here. 2. USB Port Connect to your PC. 3. AC/DC Socket Connect to adapter. Press to view the previously recorded data. 4. Memory Button Press to start or stop recording your blood pressure. 5.
The cuff used for measuring blood pressure is a delicate component of the device and should be stored carefully when not in use. The BD850 is designed such that the cuff can be stored along with the blood pressure monitor.
When you insert the batteries for the first time (see “Inserting the batteries”), the BD850 prompts you to set the current date and time. You can also adjust the date, time and user at any time by pressing and holding down the button for over 3 seconds.
3.2 Enabling the MAM (optional) The BD850 has an averaging mode to calculate an average of blood pressure readings. To enable the average mode, do the following: 1. Hold down the button for more than 3 seconds. Select your user (user 1 or 2).
3.3C Fitting the Cuff a) Pass the end of the cuff through the flat metal ring so that a loop is formed. The closure must be facing outward. (Ignore this step if the cuff has already been prepared.) b) Place the cuff over the left upper arm so that the tube is closer to your lower arm.
Comment: If it is not possible to fit the cuff to your left arm, it can also be placed on the right arm. However all measurements should be made using the same arm. Comparable blood pressure measurements always require the same conditions (Relax for several minutes before taking a measurement).
Page 16
Information for the doctor on frequent appearance of the Pulse Arrythmia Heartbeat Symbol This instrument is an oscillometric blood pressure monitor device that also analyzes pulse frequency during measurement. The instrument is clinically tested. If pulse irregularities occur during measurement, the irregular heartbeat symbol is displayed after the measurement.
5. Installation and Data Transmission a) Insert CD into CD ROM drive of your PC. The installation will start automatically. If not, click on SETUP.EXE. b) Connect the monitor via USB cable with the PC. Three horizontal bars will appear on the display and last for 3 seconds.
Malfunction Remedy The display remains empty when the device is 1. Check batteries for correct polarity. switched on. The batteries are inserted. 2. If the display is unusual, re-insert the batteries or exchange them for new ones. The pressure does not rise even though the pump is Check the connection of the cuff tube and connect running.
This warranty does not include the inflation system including the cuff and inflation bladder. The cuff is warranted for two years. The warranty does not cover damage from misuse or tampering. If you have questions regarding the operation of your monitor call the BIOS Diagnostics Blood Pressure ™...
This unit has received an A/A rating according to the B.H.S protocol and is “recommended for home use.” This is the highest grading available for blood pressure monitors. Please see the B.H.S website at www.bhsoc.org. Product using the identical measurement algorithm was tested by unaffiliated researchers using B.H.S. study protocol.
11. Contact for Support Thermor Ltd. 16975 Leslie Street Newmarket, ON L3Y 9A1 www.biosexactly.com Toll Free Help Line: 1-866-536-2289 Email: thermor@thermor-ins.com Made in China TH1012_BD850 022210...
Need help?
Do you have a question about the BD850 and is the answer not in the manual?
Questions and answers
do i have to register my new BIOS MONITOR
The provided information does not mention any requirement to register the BIOS Diagnostics BD850 monitor. Therefore, based on the available context, registration is not required.