17. Replace the housing cover, and tighten the cover
screw holding it to the actuator housing (Fig. 12).
18. Close the master switch.
19. Test the valve to make sure it opens and closes as
described in the Operation section.
20. Verify proper operation after servicing.
Fig. 12—Wiring connections and actuator
housing
ACTUATOR
HOUSING
OPENING IN
ACTUATOR
HOUSING
CONDUIT
(IF REQUIRED)
Fig. 13—Internal view of actuator housing.
ACTUATOR
HOUSING
2 TORX 20
SCREWS HOLDING
ACTUATOR HOUSING
6 IN. [152.4 MM] INTERNAL
BLACK LEADWIRES
(FROM COIL)
SOLDERLESS
CONNECTORS
GROUNDING
SCREW
COVER
SCREW
EXTERNAL
WIRES
M7302
HOLDING NUT
COIL ASSEMBLY
GROUNDING
SCREW
M7301
Fig. 14—Coil assembly fits on plunger tube
assembly
Fig. 15—Coil assembly, insulator, and cover.
CARDBOARD
INSULATOR
METAL BASE
11
V48A,F,J; V88A,J
SERVICE INFORMATION
COIL ASSEMBLY
PLUNGER TUBE
ASSEMBLY
M7303
WRAPAROUND
METAL COVER
COIL
ASSEMBLY
CARDBOARD
INSULATOR
HOOKED TOGETHER