Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Advanced Programming —
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
SELECT
CURRENTLY
OPTION READY
CHOOSE
OPTION
FUNCTION
SET OPTION
TO CHANGE
OPTION
STORED
UP
UP
OR
OR
DOWN
ENTER
ENTER
DOWN
ENTER
PRESS ENTER FOR
PRESS ENTER
PRESS UP OR DOWN
ONE SECOND TO
TO STORE
TO SCROLL DISPLAY
SELECT OPTION
PRESS UP
OPTION
THROUGH FUNCTIONS
(THE DISPLAY
OR DOWN
WILL FLASH)
TO CHANGE
OPTION
PROGRAMMING
PRESS ENTER TO
PRESS UP, DOWN
DISPLAY CURRENTLY
OR ENTER SELECT
KEYSTROKES
SET OPTION
NEXT FUNCTION
APEX FUNCTION
DISPLAY INDICATIONS
LEFT OR RIGHT
LOW POWER
"RL"
"LP"
HAND OPERATION
MODE
SINGLE OR
POWER
"PM"
"FS"
DUAL GATE
FAILURE MODE
AUTO CLOSE
SOFT START/STOP
"AC"
"SS"
TIMER
DURATION
RUN ALARM
RESET CYCLE
"RP"
"CT"
PRE-START ALARM
COUNT
MAXIMUM OPEN
MAINTENANCE ALERT
"OC"
"MA"
CURRENT
TRIGGER
MAXIMUM CLOSE
OPEN/RESET
"CC"
"OR"
CURRENT
INPUT
ADVANCED
ANTI
"AD"
"TG"
PROGRAMMING
TAILGATE
MAXIMUM
MID-TRAVEL
"RT"
"MT"
RUN TIMER
STOP POSITION
SINGLE BUTTON
ANTI-TAILGATE
"SB"
"AT"
INPUT SETUP
ENABLE
STAGGER
RADIO
"SM"
"RA"
MODE
ENABLE
STAGGER
LEARN
"ST"
"TL"
TIME
TRANSMITTERS
AUXILIARY
DELETE
"AR"
"TD"
RELAY MODE
TRANSMITTERS
REVERSE
LEARN MGT
"RD"
"ML"
DELAY TIME
TRANSMITTERS
BRAKE
ERASE MGT
"BD"
"MD"
DELAY TIME
TRANSMITTERS
CONSTANT
MOTOR TYPE
"CP"
"MO"
PRESSURE MODE
SELECTION
SHADOW LOOP
RESET TO
"SP"
"CL"
OPEN PREVENTION
FACTORY DEFAULTS
OPEN OBSTRUCTION
OBSTRUCTION
"OO"
"OT"
DETECTION TYPE, b1, b2
INPUT ACTIVE
MGT MONITIRING
REMOTE CLOSE
"MM"
"RC"
FUNCTION
OBSTRUCTION ACTIVE
CLOSE OBSTRUCTION
REMOTE OPEN
"CO"
"RO"
INPUT ACTIVE
OBSTRUCTION ACTIVE
FUNCTION
OPTIONS
"OR"
OPEN MODE OFF
SELECT
FUNCTION
PRESS UP OR
OPEN COUNTER MODE
DOWN TO CYCLE
THROUGH OPTIONS
ENTER
PRESS ENTER TO
SELECT AN OPTION
OPEN SUPERVISED MODE
OR
UP
OPEN/RESET
INPUT
OR
DOWN
FUNCTION
OPTIONS
ANTI-TAILGATE ENABLE OFF
"AT"
GATE REQUIRES AUTO OR MANUAL CLOSE
ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
ANTI-TAILGATE
PRESS ENTER TO
SELECT AN OPTION
ENABLE
FUNCTION
ENTER
PRESS ENTER
"TD"
"TD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ONE OR MORE TRANSMITTERS,
(TO EXIT WITHOUT DELETING ANY, PRESS ENTER)
TO DELETE ALL TRANSMITTERS, PRESS ENTER FOR
ENTER
2 SECONDS, OR TO PICK TRANSMITTERS GO TO NEXT STEP
PRESS UP OR DOWN TO SCROLL THROUGH THE LIST
OR
UP
DOWN
OF TRANSMITTER ID NUMBERS
THE TRANSMITTER ID NUMBER IS DISPLAYED
(TO EXIT WITHOUT DELETING, PRESS ENTER)
(TO PICK A DIFFERENT TRANSMITTER ID, PRESS UP OR DOWN)
DELETE
PRESS ENTER FOR 2 SECONDS TO DELETE THE
ENTER
TRANSMITTERS
TRANSMITTER DISPLAYED
FUNCTION
OPTIONS
"MM"
UL 325 6TH EDITION
2 MISSED SIGNALS
MONITORS BATTERY AND
RESULT IN ALARM
CONNECTION OF MGT
BEEPING
TRANSMITTER
MGT MONITORING
FUNCTION
FUNCTION
OPTIONS
"TG"
ANTI-TAILGATE FUNCTION DISABLED
ANTI-TAILGATE FUNCTION ENABLED
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
BARRIER GATES
ANTI-
PRESS ENTER TO
ONLY
SELECT AN OPTION
TAILGATE
FUNCTION
OPTIONS
"RA"
INTERNAL RADIO RECEIVER DISABLED
INTERNAL RADIO RECEIVER ENABLED
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
NOT FOR
RADIO
PRESS ENTER TO
BARRIER GATES
SELECT AN OPTION
ENABLE
FUNCTION
PRESS ENTER, "ML" WILL BLINK FOR 30 SECONDS WHILE
ENTER
THE CONTROLLER IS READY TO LEARN AN MGT
TRANSMITTER
"ML"
ACTIVATE THE MGT TRANSMITTER, THE DISPLAY WILL
FLASH "rE" - IF THE TRANSMITTER IS ALREADY ENTERED,
"DU" WILL BE DISPLAYED, IF DECODE IS BAD "ERROR" WILL
BE DISPLAYED
PRESS UP OR DOWN TO SELECT THE MGT FUNCTION:
UP
OR
DOWN
"rE" = REVERSE
"OP" = OPEN OBSTRUCTION
ENTER
PRESS ENTER TO ACCEPT THE SELECTION
LEARN MGT
DISPLAY WILL SHOW "--" FOR 5 SECONDS, THEN SHOW THE
TRANSMITTER'S ID NUMBER - REPEAT STEPS FOR
TRANSMITTERS
SECOND MGT TRANSMITTER IF USED
FUNCTION
OPTIONS
AC MOTOR ONLY
"MO"
DC MOTOR ONLY WITH BRAKING
PRESS UP OR
DC MOTOR WITH SOFT START/STOP
DOWN TO CYCLE
ALL LRA INSTALLATIONS USE D2
THROUGH OPTIONS
3 PHASE AC MOTOR
PRESS ENTER TO
SELECT AN OPTION
AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH BRAKING
MOTOR TYPE
AC MOTOR PRIMARY WITH
SELECTION
DC MOTOR BACKUP WITH SOFT START/STOP
FUNCTION
OPTIONS
"MT"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
BARRIER GATES
MID-TRAVEL
PRESS ENTER TO
ONLY
SELECT AN OPTION
STOP POSITION
FUNCTION
ENTER
"TL"
LEARN
TRANSMITTERS
FUNCTION
ENTER
"MD"
"St" = STOP
"CL" = CLOSE OBSTRUCTION
ENTER
ERASE MGT
TRANSMITTERS
FUNCTION
ENTER
"CL"
NOTE: SELECTION
MUST MATCH
MOTOR BOARD!
RESET TO
FACTORY DEFAULTS
1-800-543-4283
linearproaccess.com
Copyright © 2019 Nortek Security & Control, LLC
MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)
SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS
NOT FOR
BARRIER GATES
PRESS ENTER (ONCE FOR EACH TRANSMITTER,
UP TO 40 TRANSMITTERS TOTAL)
"TL" WILL BLINK FOR 30 SECONDS WHILE
THE CONTROLLER IS READY TO
LEARN A TRANSMITTER
ACTIVATE THE TRANSMITTER
DISPLAY WILL SHOW "- -" THEN THE
TRANSMITTER ID NUMBER - IF TRANSMITTER
IS ALREADY ENTERED, "dU" WILL BE DISPLAYED,
IF DECODE IS BAD "ERROR" WILL BE DISPLAYED
PRESS ENTER
"MD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ALL MGT TRANSMITTERS
TO DELETE ALL MGT TRANSMITTERS, PRESS ENTER FOR
2 SECONDS, (TO EXIT WITHOUT DELETING ANY, QUICKLY
PRESS ENTER)
THE DISPLAY WILL SHOW "DELETE ALL" AND THE
CONTROLLER RETURNS TO PROGRAMMING MODE
WHILE "CL" IS DISPLAYED, PRESS ENTER
ALL PROGRAMMED DATA WILL BE CLEARED
AND THE FACTORY DEFAULTS WILL BE
STORED IN MEMORY.
NOTE: THIS FUNCTION WILL NOT ERASE
TRANSMITTERS, CURRENT SENSE VALUES,
OR MOTOR TYPE.
231663 E
Need help?
Do you have a question about the PRO Access APeX-II v2.1 and is the answer not in the manual?