Download Print this page

Linear PRO Access APeX-II v2.1 Quick Programming Manual page 2

Gate controller basic programming

Advertisement

Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Advanced Programming —
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
SELECT
CURRENTLY
OPTION READY
CHOOSE
OPTION
FUNCTION
SET OPTION
TO CHANGE
OPTION
STORED
UP
UP
OR
OR
DOWN
ENTER
ENTER
DOWN
ENTER
PRESS ENTER FOR
PRESS ENTER
PRESS UP OR DOWN
ONE SECOND TO
TO STORE
TO SCROLL DISPLAY
SELECT OPTION
PRESS UP
OPTION
THROUGH FUNCTIONS
(THE DISPLAY
OR DOWN
WILL FLASH)
TO CHANGE
OPTION
PROGRAMMING
PRESS ENTER TO
PRESS UP, DOWN
DISPLAY CURRENTLY
OR ENTER SELECT
KEYSTROKES
SET OPTION
NEXT FUNCTION
APEX FUNCTION
DISPLAY INDICATIONS
LEFT OR RIGHT
LOW POWER
"RL"
"LP"
HAND OPERATION
MODE
SINGLE OR
POWER
"PM"
"FS"
DUAL GATE
FAILURE MODE
AUTO CLOSE
SOFT START/STOP
"AC"
"SS"
TIMER
DURATION
RUN ALARM
RESET CYCLE
"RP"
"CT"
PRE-START ALARM
COUNT
MAXIMUM OPEN
MAINTENANCE ALERT
"OC"
"MA"
CURRENT
TRIGGER
MAXIMUM CLOSE
OPEN/RESET
"CC"
"OR"
CURRENT
INPUT
ADVANCED
ANTI
"AD"
"TG"
PROGRAMMING
TAILGATE
MAXIMUM
MID-TRAVEL
"RT"
"MT"
RUN TIMER
STOP POSITION
SINGLE BUTTON
ANTI-TAILGATE
"SB"
"AT"
INPUT SETUP
ENABLE
STAGGER
RADIO
"SM"
"RA"
MODE
ENABLE
STAGGER
LEARN
"ST"
"TL"
TIME
TRANSMITTERS
AUXILIARY
DELETE
"AR"
"TD"
RELAY MODE
TRANSMITTERS
REVERSE
LEARN MGT
"RD"
"ML"
DELAY TIME
TRANSMITTERS
BRAKE
ERASE MGT
"BD"
"MD"
DELAY TIME
TRANSMITTERS
CONSTANT
MOTOR TYPE
"CP"
"MO"
PRESSURE MODE
SELECTION
SHADOW LOOP
RESET TO
"SP"
"CL"
OPEN PREVENTION
FACTORY DEFAULTS
OPEN OBSTRUCTION
OBSTRUCTION
"OT"
"OO"
INPUT ACTIVE
DETECTION TYPE, b1, b2
MGT MONITIRING
REMOTE CLOSE
"MM"
"RC"
FUNCTION
OBSTRUCTION ACTIVE
CLOSE OBSTRUCTION
REMOTE OPEN
"CO"
"RO"
INPUT ACTIVE
OBSTRUCTION ACTIVE
FUNCTION
OPTIONS
ADVANCED PROGRAMMING FUNCTIONS
"AD"
WILL NOT BE DISPLAYED
SELECT
FUNCTION
ADVANCED PROGRAMMING OPTIONS
WILL BE DISPLAYED
ENTER
PRESS UP OR
DOWN TO CYCLE
OR
THROUGH OPTIONS
UP
ADVANCED
PRESS ENTER TO
SELECT AN OPTION
PROGRAMMING
OR
DOWN
FUNCTION
OPTIONS
"SM"
DISABLES STAGGER FUNCTION
SETS THIS OPERATOR FOR
PRESS UP OR
DELAYED OPEN
DOWN TO CYCLE
THROUGH OPTIONS
SETS THIS OPERATOR FOR
PRESS ENTER TO
DELAYED CLOSE
SELECT AN OPTION
NOT FOR
STAGGER
BARRIER GATES
MODE
FUNCTION
OPTIONS
SET TIMER VALUE
"RD"
1 TO 9 SECONDS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
REVERSE
DELAY TIME
FUNCTION
OPTIONS
STANDARD OPERATION
"SP"
SHADOW LOOP INHIBITS CLOSING ONLY
OPEN INHIBIT ON, SHADOW LOOP INHIBITS
OPENING AND CLOSING
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
SHADOW LOOP
PRESS ENTER TO
SELECT AN OPTION
OPEN PREVENTION
FUNCTION
OPTIONS
SOFT START DISABLED
"SS"
SET SOFT START DURATION TIME
FROM 1 TO 10 SECONDS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
SOFT START/STOP
PRESS ENTER TO
SELECT AN OPTION
DURATION
FUNCTION
"RT"
NOTE: ADVANCED PROGRAMMING
WILL STAY ENABLED AFTER
MAXIMUM RUN
EXITING PROGRAMMING UNTIL
THE GATE CYCLES 50 TIMES
TIMER
FUNCTION
"ST"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
NON-LRA DUAL
STAGGER
PRESS ENTER TO
SELECT AN OPTION
DELAY TIME
GATES ONLY
FUNCTION
"BD"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
BRAKE
DELAY TIME
FUNCTION
"LP"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
NOT FOR
LOW POWER
THE FIRE DEPARTMENT INPUT
BARRIER GATES
MODE
WILL ALWAYS WAKE UP CONTROLLER
FUNCTION
PRESS ENTER TO START THE CYCLE COUNT DISPLAY
"CT"
1ST DISPLAY
EXAMPLE ABOVE SHOWS 10,420 CYCLES
NOTE: PRESS ENTER FOR 2 SECONDS
RESET CYCLE
WHILE THE "CT" FUNCTION IS DISPLAYED
COUNT
TO RESET THE CYCLE COUNT TO ZERO
OPTIONS
FUNCTION
DISPLAY SHOWS CURRENT
"SB"
MAXIMUM RUN TIME SETTING
ENTER
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP OR DOWN TO CHANGE THE
MAXIMUM RUN TIME (10-99 SECONDS)
SINGLE BUTTON
ENTER
PRESS ENTER TO STORE THE VALUE
INPUT SETUP
OPTIONS
FUNCTION
"AR"
STAGGER TIMER DISABLED
PRESS UP OR
SET STAGGER DELAY VALUE
DOWN TO CYCLE
THROUGH OPTIONS
1 TO 99 SECONDS
PRESS ENTER TO
SELECT AN OPTION
NOT FOR
BARRIER GATES
NON-LRA DUAL
AUXILIARY
GATES ONLY
RELAY MODE
OPTIONS
FUNCTION
SET TIMER VALUE
"CP"
0 TO 3 SECONDS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
NOT FOR
BARRIER GATES
NOT FOR
CONSTANT
BARRIER GATES
PRESSURE MODE
OPTIONS
FUNCTION
LOW POWER MODE DISABLED
"FS"
LOW POWER MODE #1
PRESS UP OR
RADIO WILL WAKE AND ACTIVATE,
DOWN TO CYCLE
REVERSE LOOP WILL JUST WAKE
THROUGH OPTIONS
LOW POWER MODE #2 - RADIO OR
PRESS ENTER TO
OPEN LOOP WILL WAKE AND ACTIVATE,
SELECT AN OPTION
REVERSE LOOP WILL JUST WAKE
POWER
FAILURE MODE
FUNCTION
"MA"
2ND DISPLAY
3RD DISPLAY
4TH DISPLAY
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
DECIMAL POINT LIT
SELECT AN OPTION
ON 4TH DISPLAY
MAINTENANCE
ALERT TRIGGER
OPTIONS
SINGLE INPUT WILL CYCLE OPERATOR
IN ORDER OF OPEN-STOP-CLOSE-STOP
SINGLE INPUT WILL OPEN OPERATOR,
IF OPERATOR IS ALREADY OPEN, SINGLE
INPUT WILL CLOSE OPERATOR
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
OPTIONS
AUXILIARY RELAY DISABLED
AUXILIARY RELAY USED FOR
MAGLOCK CONTROL
AUXILIARY RELAY USED FOR
MAGLOCK OR SOLENOID CONTROL
3 SECOND DELAY TO RE-ENERGIZE
AUXILIARY RELAY USED FOR
TICKET DISPENSER CONTROL
AUXILIARY RELAY USED FOR
WARNING STROBE LIGHT
AUXILIARY RELAY USED FOR
CONNECTION TO ALARM DEVICE
OPTIONS
CONSTANT PRESSURE SET TO OFF
(MOMENTARY PRESSURE ON)
OPEN BUTTON SET FOR
CONSTANT PRESSURE
CLOSE BUTTON SET FOR
CONSTANT PRESSURE
OPEN AND CLOSE BUTTONS BOTH SET
FOR CONSTANT PRESSURE
OPTIONS
SET TO FAIL SAFE MODE
SET TO FAIL SECURE MODE
SET TO OPEN IMMEDIATE MODE
DC MODELS
SET TO CLOSE
IMMEDIATE MODE
ONLY
OPTIONS
DISABLES THE MAINTENANCE ALERT
FUNCTION
SETS THIS MAINTENANCE ALERT TRIGGER
FOR 5, 10, 15, OR 25 THOUSAND CYCLES
RESETS THE MAINTENANCE ALERT
INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO

Advertisement

loading
Need help?

Need help?

Do you have a question about the PRO Access APeX-II v2.1 and is the answer not in the manual?

Subscribe to Our Youtube Channel