ELIS PLZEŇ a. s.
Operating flow rates and flow velocities for various sensor sizes

4.1.2. Operating pressure of measured liquid

The standard sensor versions have the following pressure ratings:
Flanges according to EN1092-1
Nominal size of sensor
Flanges according to ASME B16.5
Nominal size of sensor
On request, any sensor can be supplied for pressure rating PN 6 to PN 40. The choice of pressure rating is
primarily derived from the maximum admissible working pressure of the measured liquid, considering the
nominal size and pressure rating of the flanges on the adjoining piping. Consideration shall also be given to
the liquid temperature.
Relationship between operating pressure and temperature of the measured liquid.
ELIS PLZEŇ a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, Phone: +420/377 517 711, Fax: +420/377 517 722
Design, Assembly and Service Manual
Electromagnetic flowmeter FLONET FN20xx.1
DN 6 to DN10
DN 15 to DN 50
DN 65 to DN 200
DN 250 to DN 300
NPS ½" to 12"
Pressure rating
PN 25
PN 40
PN 16
PN 10
Pressure rating
Class 150