LEGEND - Password Level: S = Service; O = OEM; S/O = View - Service, Write - OEM; Info = Info Menu; Ser = Service Menu
Parameter
Shaded Parameters = Frequently Used
Parameter Name
Number
PW Level
515.00
Actuator Purge Position
515.01
Actuator Activation
560
Analog Input Type
654
Analog Input Signal
701-711
Fault History
920
Target Speed %
935
Actual Speed RPM
936
Actual Speed %
951
Incoming Voltage
954
Flame Signal
SCC Inc.
Default
Range
Read only
S
S/O
1
0-1
S
2
0-2
600 Level: Analog Input Configuration
S
1
0-5
Ser
Read only
Ser
Read only
500 Level: Actuator Configuration
Determines the position of the actuator during prepurge and postpurge. Cannot be changed on the
LME75. The actuator will always purge at high fire.
Used to activate or deactivate the use of an actuator. If set to 0, parameter 560 must also be set to 0.
0 = deactivated (no actuator)
1 = activated (with actuator)
Sets the type of input being used to control the actuator.
0 = no actuator / 3-position input
1 = not used
2 = analog input
Sets the type of input signal being connected to terminal X65 or X5-03 when parameter 560 is set to 2.
This input signal is used to determine the actuator position during operation.
0 = 3-position
1 = 0-10 VDC
2 = 0-135 Ohm
3 = 0-20 mA
4 = 4-20 mA with lockout when input is less than 4 mA
5 = 4-20 mA without lockout when input is less than 4 mA
700 Level: Fault History
Shows the current status (fault) along with the 10 most recent faults. 701 = current status, 702 = most
recent fault, 703 = next most recent fault, etc. Each fault has indices that provide additional information
about the fault:
Index 00 = fault code
Index 01 = start number
Index 02 = phase
Index 03 = load
900 Level: Operational Data
Not used on the LME75. Will always display as a "-".
Not used on the LME75. Will always display as a "-".
Not used on the LME75. Will always display as a "-".
Displays the real time mains voltage. Measured at terminal X3-04 pin 4 (neutral) and pin 5 (line).
Displays the raw flame signal from 0-100% for any flame scanner type. A flame failure occurs when the
flame signal drops below 20% for the time period specified by parameter 217.01.
Index 00 = flame rod (input X10-06.2)
Index 01 = flame scanner QRA75/QRI (input X10-05.1)