Kenwood NX-411 Service Manual page 51

900mhz digital transceiver
Hide thumbs Also See for NX-411:
Table of Contents

Advertisement

Item
Panel tuning mode
10. MSK
1) Adj item: [An MSK]
Deviation *4
Adjust: [
Deviation meter
[Analog
LPF: 15kHz
Narrow]
HPF: OFF
2) Adj item:
[AnH MSK] →
[AnH MSK] (TA)
Adjust: [
PTT: ON
Press [ ] key to
store the adjust-
ment value.
11. CW ID
1) Adj item: [Nv CWID]
Deviation *4
Adjust: [
Deviation meter
[NXDN Very
LPF: 15kHz
Narrow]
HPF: OFF
PTT: ON
Press [ ] key to
store the adjust-
ment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 53.
12. VOX 1
1) Adj item: [VOX1]
Adjust: [
AG: 1kHz/45mV at
MIC terminal
13. VOX 10
1) Adj item: [VOX10]
Adjust: [
AG: 1kHz/3mV at
MIC terminal
ADJUSTMENT
Condition
PC test mode
equipment
1)Adj item: [MSK
Deviation
]
Deviation (Analog
meter
Narrow)]
Oscillo-
Deviation meter
scope
LPF: 15kHz
HPF: OFF
2) Adj item: [High],
[High (TA)]
]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [CW ID
]
Deviation (NXDN
Very Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [VOX 1]
AG
]
AG: 1kHz/45mV at
MIC terminal
1) Adj item: [VOX 10]
]
AG: 1kHz/3mV at
MIC terminal
Measurement
Test-
Unit Terminal
Unit
Panel ANT
Panel [Panel
Panel Universal
connector
NX-411
Adjustment
Specifi cations /
Parts
Method
Write the value as
1.50kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
[
],
value)
[
]
[PC test
mode]
[ ],[ ]
Write the value as
1.10kHz±0.10kHz
followings.
359 (Reference
value)
[Panel tuning mode]
After apply signal
from AG, press
[ ] key to store the
adjustment value.
[PC test mode]
After apply signal
from AG, press
[Apply] button to
store the adjust-
ment value.
Remarks
51