■ Adjustment item supplement
Adjustment Item
LCD Contrast
Counterclockwise Volume
Clockwise Volume
Receive Assist
Transmit Assist
Frequency
RTC (Real-time clock)
High Transmit Power
Low Transmit Power
Balance
Maximum Deviation
(NXDN Narrow/Very Narrow)
Maximum Deviation
(Analog Narrow)
QT Deviation
DQT Deviation
LTR Deviation
DTMF Deviation
MSK Deviation
CW ID Deviation
VOX 1
VOX 10
RSSI Reference
Open Squelch
Low RSSI
High RSSI
Tight Squelch
Battery Warning Level
ADJUSTMENT
The contrast of LCD display can be changed.
"Counterclockwise Volume" is adjusted at the minimum volume position.
"Clockwise Volume" is adjusted at the maximum volume position.
These adjustments can correct the volume variation.
Both "Counterclockwise Volume" and "Clockwise Volume" must be adjusted.
(The curve data of volume is applied.)
The lock voltage of VCO (Receive) is adjusted.
This item must be adjusted before all adjustment items for receiver section are adjusted.
The lock voltage of VCO (Transmit) is adjusted.
This item must be adjusted before all adjustment items for transmitter section are adjusted.
Frequency stability is adjusted under receiving condition with SSG.
The SSG needs 0.001ppm accuracy so please use a standard oscillator if necessary.
This item can be adjusted only in PC Test Mode so that the adjustment value is not changed easily.
Real-Time Clock (RTC) is adjusted.
This item uses the internal clock.
(Any measurement equipment is not required.)
High Transmit Power is adjusted.
Low Transmit Power is adjusted.
The transmit audio frequency response is adjusted.
This item is adjusted so that the deviation of 2kHz becomes the same deviation of 20Hz.
This item must be adjusted before all adjustment items for deviations are adjusted.
Maximum Deviation of NXDN (Narrow/Very Narrow) is adjusted.
Maximum Deviation of Analog (Narrow) is adjusted.
This item must be adjusted before all adjustment items for tone deviations are adjusted.
Note: "Maximum Deviation (Analog Narrow)" must be adjusted before "CWID Deviation (NXDN Very
Narrow)" is adjusted.
QT tone deviation is adjusted.
DQT tone deviation is adjusted.
LTR tone deviation is adjusted.
DTMF tone deviation is adjusted.
MSK tone deviation is adjusted.
CW ID tone deviation is adjusted.
CW ID is used to inform the others who is transmitting on a 6.25-kHz spacing channel.
(In FCC rule, Analog mode or CW ID is required for each channel-spacing.)
VOX sensitivity at "VOX 1" is adjusted.
VOX sensitivity at "VOX 10" is adjusted.
The minimum RSSI level for scan stop is adjusted.
The squelch level at level "5" is adjusted.
" is adjusted.
RSSI display level "
Both "Low RSSI" and "High RSSI" must be adjusted.
(The curve data of RSSI level is applied.)
The squelch level at level "9" is adjusted.
Battery Warning Level (LED blinking level) is adjusted.
Battery Warning Level minus 0.4V is the transmission inhibited level.