-P- Alarm settings
DESCRIPTION
High pressure alarm set point (transducer B3; B4)
High pressure alarm differential (transducer B3; B4)
Low pressure alarm, summer
Low pressure alarm, winter
Low pressure alarm, defrost
Low pressure differential
Start low pressure alarm delay
Operating low pressure alarm delay
Start flow switch alarm delay
Operating flow switch alarm delay
Number OFF cycles per auto reset alarm
Max. period for auto. reset alarm
Selection alarm with auto reset: compressor thermal switch
Selection alarm with auto reset: fan thermal switch
Selection alarm with auto reset: low pressure switch
Selection alarm with auto reset: high pressure switch
-r- Temperature control
Upon entering this submenu the dynamic set point tempera-
DESCRIPTION
COOL set point
HEAT set point
Temperature setting band
COOL set point lower limit
COOL set point upper limit
HEAT set point lower limit
HEAT set point upper limit
Enable dynamic set point
Max. compensation value
Compensation in COOL: start temperature
Compensation in COOL: end temperature
Compensation in HEAT: start temperature
Compensation in HEAT: end temperature
Type of temperature setting
Type of setting with input probe
Type of integration in each adjustment P+1
Max. time call increase (output setting)
Min. time call increase (output setting)
Max. time call decrease (output setting)
Min. time call decrease (output setting)
Temp. differential within flow varies increase & decrease time (output setting)
Device forced OFF in COOL cycle (output setting)
Device forced OFF in HEAT cycle (output setting)
Enable dynamic set point
Min. dynamic set point
Máximo set point dinámico
RANGE
0/99.9
0/99.9
0/99.9
0/99.9
0/99.9
0/99.9
0-999
0-999
0-999
0-999
0 - 4
0 - 99
AUTOMATIC / MANUAL
AUTOMATIC / MANUAL
AUTOMATIC / MANUAL
AUTOMATIC/ MANUAL
tures (if this function is enabled) are displayed. Press Up to
access the configuration menu.
RANGE
N/Y
-99.9/99.9
-99.9/99.9
-99.9/99.9
-99.9/99.9
-99.9/99.9
INPUT/OUTPUT
PROPORTIONAL/P+I
0/9999
0/9999
0/9999
0/9999
0/9999
-99.9/99.9
-99.9/99.9
-99.9/99.9
Y/N
-99.9/99.9
-99.9/99.9
UNIT
VALUE
bar
41
bar
10
bar
3
bar
2
bar
1
bar
1
s
60
s
0
s
20
s
5
1
m
60
AUTOMATIC
AUTOMATIC
AUTOMATIC
AUTOMATIC
UNIT
VALUE
°C
12
°C
40
°K
3
°C
6
°C
15
°C
25
°C
45
-
N
°K
5
°C
25
°C
35
°C
7
°C
12
-
INPUT
PROPORTIONAL
s
600
s
20
s
20
s
10
s
10
°C
2
°C
5
°C
47
N
°C
0
°C
5
41