12.2

Inside the CS4

In the CS4 intrusion detection control unit the gateway can be mounted on the L-
shaped plate on the right side of some of the standard housings.
To properly mount the Gateway GW-21, you must follow the procedure described b e-
low:
4. remove the K3H010 board;
5. remove the L-shaped plate from the chassis;
6. unscrew the four plastic guided used to host the K1D080 and K1H021 boards for
Cerloop;
7. mount the four spacers provided with GW-21 on the L-shaped plate;
8. mount the L-shaped plate inside the chassis;
9. mount the connection board of the GW-21;
10. mount the CPU board and the expansion board, if needed, on the connection
board
11. mount again in its place the K3H010 board
12. Please follow this sequence, because the screws used to mount the L-shaped
plate inside the chassis are under the connection board.
L-shaped plate
GW-21
K3H010
Fig. 21 Slots in the CS4 control unit
E1481b
06.2000