Appendix C: Dil-Switches Description - Siemens Cerberus GW-21 Technical Manual

Lmsmodular gateway
Table of Contents

Advertisement

JUMPER
FUNCTION
S1.1
Configuration
S1.2
Cerban vitality
S1.3
Ciphering (only on two level network)
S1.4
subsystem type UART 1
S1.5
subsystem type UART 1
S1.6
subsystem type UART 1
S1.7
baud rate UART 1
S1.8
baud rate UART 1
S2.1
baud rate UART 1
S2.2
subsystem type UART 2
S2.3
subsystem type UART 2
S2.4
subsystem type UART 2
S2.5
baud rate UART 2
S2.6
baud rate UART 2
S2.7
baud rate UART 2
S2.8
subsystem type UART 3
S3.1
subsystem type UART 3
S3.2
subsystem type UART 3
S3.3
baud rate UART 3
S3.4
baud rate UART 3
S3.5
baud rate UART 3
S3.6
subsystem type UART 4
S3.7
subsystem type UART 4
S3.8
subsystem type UART 4
S4.2
baud rate UART 4
S4.3
baud rate UART 4
S4.4
baud rate UART 4
S4.5
subsystem type UART 5
S4.6
subsystem type UART 5
S4.7
subsystem type UART 5
S4.8
baud rate UART 5
S5.1
baud rate UART 5
S5.2
baud rate UART 5
S5.3
subsystem type UART6
S5.4
subsystem type UART6
S5.5
subsystem type UART6
S5.6
baud rate UART 6
S5.7
baud rate UART 6
S5.8
baud rate UART 6
BAUD RATE
UART
Spare
1
S1.7
ON
S1.8
ON
ON
S2.1
2
S2.5
ON
S2.6
ON
S2.7
ON
3
S3.3
ON
S3.4
ON
S3.5
ON
4
S4.2
ON
S4.3
ON
S4.4
ON
5
S4.8
ON
S5.1
ON
S5.2
ON
6
S5.6
ON
S5.7
ON
ON
S5.8
Siemens Building Technologies
Cerberus Division
11
Appendix C:
DIL-Switches Description
VALUE
9600 4800 2400 1200 600
300
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
OFF
ON
OFF
O N
OFF
ON
ON
OFF OFF
O N
O N
OFF OFF
ON
ON
ON
OFF OFF OFF OFF
Fig. 19
Configuration by Flash EPROM
Configuration by dip-switches
Vitality message filtered
Vitality message not filtered
Ciphering enabled
Ciphering disabled
150
OFF
OFF
Dip switches
UART JUMPER cz10/cs11
cs4/cz12
/cc60
1
S1.4
ON
OFF
OFF
S1.5
OFF
ON
S1.6
OFF
OFF
2
S2.2
ON
OFF
S2.3
OFF
ON
OFF
S2.4
OFF
OFF
3
S2.8
ON
OFF
S3.1
OFF
ON
S3.2
OFF
OFF
4
S3.6
ON
OFF
OFF
S3.7
OFF
ON
S3.8
OFF
OFF
5
S4.5
ON
OFF
S4.6
OFF
ON
S4.7
OFF
OFF
OFF
6
S5.3
ON
OFF
S5.4
OFF
ON
S5.5
OFF
OFF
S1.1
OFF
ON
S1.2
OFF
ON
S1.3
ON
OFF
CMX/ CCTV Burle
STT SEEP/CDDL/
LMS, two level
Cf9003
o Cerloop
Cerpass/Size
network
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
O N
ON
OFF
O N
ON
O N
ON
27
E1481b