ProMinent DULCOMARIN II DXM Series Supplementary Instructions Manual

ProMinent DULCOMARIN II DXM Series Supplementary Instructions Manual

A module (actuator module, pumps and standard signal outputs ma)

Advertisement

Quick Links

Supplementary Instructions
®
DULCOMARIN
II, A Module
(Actuator Module, Pumps and
Standard Signal Outputs mA)
DXMaA
u l e
A - M o d
___ ___ ___ ___ ___ ___
DXMa
Please enter the identcode of your module!
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Part No. 986906
ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany
BA DC 048 12/08 GB

Advertisement

loading

Summary of Contents for ProMinent DULCOMARIN II DXM Series

  • Page 1 Please carefully read these operating instructions before use! · Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Part No. 986906 ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany BA DC 048 12/08 GB...
  • Page 2 Imprint: Supplementary Instructions DULCOMARIN ® II, A Module (Actuator Module, Pumps and Standard Signal Outputs mA) DXMaA © ProMinent Dosiertechnik GmbH, 2004 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany Phone: +49 6221 842-0 Fax: +49 6221 842-419 info@prominent.com www.prominent.com...
  • Page 3: Table Of Contents

    Page Identcode ..................4 About this Module ..............5 Safety Chapter ............... 5 Storage and Transport ............5 Mounting and Installation ............. 5 Technical Data ............... 6 Terminal Assignment ............6 Terminal Connection Diagram ..........7 ProMinent ® Page 3...
  • Page 4: Identcode

    II, series DXC These modules can be ordered via the identcode of the DXC (see “Operating Instructions Multi-Channel Measuring and Control System ® DULCOMARIN II Swimming Pool Controller and Disinfection Controller DXCa, Part 1: Mounting and Installation”). ProMinent ® Page 4...
  • Page 5: About This Module

    In case of several standard signal lines, a multi-channel isolating amplifier can be used. ProMinent recommends 4-channel isolating amplifiers of the type LC-TV-4I.4I of the company of Rinck (www.rinck-electronic.de) or of the type 6185D of the company of PR Electronics (www.prelectronics.de) to connect up to 4 standard signal lines.
  • Page 6: Technical Data

    Digital input 2 error pump Digital input 3 pH value Power output 0/4-20 mA 1 I out 1 control variable pH lowering control variable pH raising control variable chlorination control variable flocculation control variable redox/ORP (recorder connection) ProMinent ® Page 6...
  • Page 7: Terminal Connection Diagram

    (recorder connection) Terminal Connection Diagram Extra-low voltage Digital inputs Standard signal outputs Relay outputs DXMaA 0/4 - 20 mA I out 1 I out 2 I out 3 I out 4 Internal External ProMinent ® Page 7...
  • Page 8 Technical changes reserved. ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany Phone: +49 6221 842-0 Fax: +49 6221 842-419 info@prominent.com www.prominent.com ProMinent ® Page 8...