3 Short Overview – the MSX
The power stage type MSX
A
and 60 to 120 V
PEAK
chopper type current control.
+
The MSX
is designed for 19"/3U racks and connected by a 48-pin connector (type F) acc.
The + of the power stage ZMX
TM
Comm
for Windows
all setting options.
The operating parameters – run current, step resolution and preferential direction – can be
set either by rotary switches (rotary switch mode) or by ServiceBus (ServiceBus mode).
The ServiceBus enables configuration, programming and diagnostic via PC.
Front view of MSX without panel
Motor currents from 1.1 to 15.4 A
Run and stop current can be individually set in 100 mA steps via ServiceBus. The Boost
current is activated via ServiceBus, too.
+
The MSD2
power stage automatically switches back to stop current if no control pulses
arrive.
MA 2128-A004 EN
+
Power Stage
+
is used for bipolar control of two-phase stepper motors at 15
with Phytron´s well-tried technology, the enhanced 4 quadrant
DC
stands for "operation with ServiceBus" by ServiceBus-
+
®
. The configuration software is included in delivery for easy use of
Peak
Motor currents from 1.1 to 15.4 A
Supply voltage from 60 to 120 V
Step resolution from full step to
1/20 step
Configuration of the power stage in
ServiceBus
Short-circuit proof over and between
the phases and towards ground
48-pin connector
acc. to DIN 41612, version F
8