6.2 Mains Supply Unit

+
The MSX
power stage can be supplied by means of an unregulated filtered DC voltage
from 60 to 120 V
.
DC
Admissible voltage range: 40 to 160 V
The voltage must not drop under 40 V or rise over 160 V, not even for a short time
(> 1 msec). If the limits are exceeded the error output opens. The drive is deactivated at
the same time.
Mains supply unit
A line filter is recommended with the following insert loss at 50 in the range of
0.15...30 MHz:
f/MHz
a/dB (line-to-ground)
(asymmetr. signals)
a/dB (line-to-line)
(symmetr. signals)
e. g. CORCOM 10ET1
DC
0.15
0.5
1
36
47
42
52
70
70
23
2
5
10
42
40
42
70
65
55
phytron
20
30
42
45
50
60
MA 2128-A004 EN