9 Putting into Service

Please follow the described order when you put into service the MSX
1. Connect the MSX
2. All connectors and screw terminals must only be connected or removed when the
module is disconnected from the mains.
3. Download driver and software from the Phytron website
(https://www.phytron.eu/support/downloads/software-download/).
4. Install the driver and the communication software ServiceBus-Comm
5. Connect the USB-RS485 converter to the PC and the MSX+ power stage.
6. Start the program after successful installation.
7. Connect the input signals to the input Control pulses and Direction.
8. Check that the supply voltage is the same as on the MSX
plate.
9. Power on the mains.
10. Start now.
WARNING – Risk of damage due to incorrect motor current setting!
The motor gets too hot!
- Deactivate the Boost function if it is used continuously.
- Adjust the motor current setting to the motor type (see motor's data).
DANGER - Danger of electric arcing!
During electrical installation the cable, connector or similar may be energised.
-
Always switch off the supply voltage before connecting or disconnecting any
wires or connectors at the power stage. Do not unplug the connector while
powered
IMPORTANT
i
If the motor stops during acceleration, reduce the acceleration and/or maximum
frequency values. Incorrect programming of the motor's rated current may also
cause this problem.
MA 2128-A004 EN
+
acc. to protective measure in chap. 3.
34
+
:
TM
.
module's identification
+