INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1.
CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C.
power is supplied to the unit.
CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
2.
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon-
necting the unit connector.
3.
CAUTION – This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary.
4.
CAUTION – Installation and servicing should be performed by qualified personnel only. De-energize before
opening.
The ILB is for use with grounded LED luminaires listed to UL standards. Not for use in heated air outlets or
5.
hazerdous locations.
6.
The ILB requires an unswitched A.C. power source of 120 to 277 volts, 50/60 Hz.
The ILB and A.C. driver must be on the same branch circuit.
7.
8.
Do not mount near gas or electric heaters.
The ILB should be mounted in locations and at heights where it will not readily be subjected to tampering by
9.
unauthorized personnel.
10.
The ILB will supply 10-60 VDC output at the individual rated specification for 90 minutes. See individual units
for output specifications.
11.
Suitable for use in damp locations and plenum spaces.
12.
Suitable for Luminaires, recessed Type IC (intended for insulation contact).
13.
For use in 0° C minimum, 55° C maximum ambient temperatures.
14.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with UL specifications.
15.
Do not use this equipment for other than intended use.
16.
Install in accordance with the National Electrical Code and local regulations.
17.
Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before
final installation. See addendum for compatibility and covered luminaire requirements.
SAVE THESE INSTRUCTIONS
EMERGENCY LED DRIVER FOR USE
WITH LED LUMINAIRES IDENTIFIED IN
THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS
E473237
CLASS 2 OUTPUT
ILB-CP
'A' MOUNTING DESIGN
EMERGENCY LIGHTING EQUIPMENT
FOR LED
Patented

Advertisement

loading

Summary of Contents for IOTA ILB-CP Series

  • Page 1 ILB-CP ‘A’ MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit.
  • Page 2: Installation Instructions

    Chart for output specifications of the unit being installed. 1. The ILB-CP series has been evaluated to and found compliant to UL standard 924. The as-installed performance of system must meet or exceed all Federal, State, and Local code requirements.
  • Page 3: Completing Installation

    LED INPUT (-) LED OUTPUT (+) LOAD DRIVER WHITE COMMON WHT/BLK RED (+) WHT/BLK BLUE (-) IOTA ILB-CP RED/WHT (+) EMERGENCY DRIVER WHITE UNSWITCHED BLUE/WHT (-) BLK/ORG (120 TO 277V, 50/60HZ) 24/7 POWER UNIT ATTENTION: DO NOT MATE UNIT CONNECTOR UNTIL CONNECTOR INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED.
  • Page 4: Testing And Maintenance

    TESTING & MAINTENANCE Pressing the TBTS turns off the light on the TBTS and forces the unit into emergency mode, interrupting power to the designated A.C. driver. The LED load is now being lit by the ILB unit. After releasing the TBTS, the fixture returns to normal operation after a momentary delay.
  • Page 5 The purpose of this addendum is to sufficiently identify electrical compatibility and predictable emergency light output of the LED luminaire when used with the IOTA ILB-CP Series LED emergency drivers. Verification of these operating traits does not constitute a code-compliant, as-installed emergency egress system. It is still the responsibility of the Designer/ Specifier to assure appropriate light levels are achieved during emergency operation of the luminaire in accordance with Federal, state and local municipal codes regarding path of egress illumination.

This manual is also suitable for:

Ilb-cp05Ilb-cp10Ilb-cp12Ilb-cp07Ilb-cp20Ilb-sl-cp05 ... Show all