Initial Setup - Conair Thermolater vacuTrac User Manual

Positive/negative pressure water temperature controller with tw-1 or tw-2 microprocessor
Table of Contents

Advertisement

I
S
NITIAL
ETUP
NOTE: All dip switch illustra-
tions in this manual show
switches 7 and 8 set to ON.
If you have an Isolated
Circuit model, these switch-
es should be set to OFF. Do
not change the factory set-
tings of these dip switches.
3-8
I
NSTALLATION
WARNING: Electric shock hazard
This equipment is powered by high voltage. Always
disconnect and lock out the main power source
before opening the unit or the electrical enclosure to
modify factory settings. Failure to disconnect and
lock out the main power source can result in severe
personal injury.
The factory-set parameters and operating modes will satisfy
most applications. But you can change some settings and
enable or disable features as needed.
You can modify the parameters for high and low process tem-
perature deviation warnings from the control panel.
S
S
D
ETTING
ETPOINT
EVIATION
Dip switches on the motherboard inside the TW-1 and
TW-2 electrical enclosure allow you to:
8 7 6 5 4 3 2 1
Dipswitch Configuration
No.
OFF
1
Display units in °F
2
Auto Tune disabled
3
Passcode protect
*
4
Auto Start disabled
*
5
Control point protect
6
Test Mode disabled
7
Controller type selection
8
Controller type selection
* Available only on TW-2 models.
† Switches 7 and 8 must be ON for Direct Injection and Closed Circuit
models. Switches 7 and 8 must be OFF for Isolated Circuit models. Do
not change these settings.
To change the dip switch settings, see the appropriate topic
on the following pages.
Thermolator TW-1 and TW-2
P
ARAMETERS
❒ Select the units of measure for tem-
perature displays.
❒ Enable password protection.
❒ Enable the Auto Tune.
❒ Enable the Auto Start feature.
❒ Enable the Test Mode.
❒ Select the source point of tempera-
ture control.
Display units °C
Auto Tune enabled
Password reset/modify
Auto Start enabled
Control point source select
Test mode enabled
Controller type selection
Controller type selection
See
.
ON
UGH015/0100