Preparing For Installation - Conair Thermolater vacuTrac User Manual

Positive/negative pressure water temperature controller with tw-1 or tw-2 microprocessor
Table of Contents

Advertisement

The Thermolator is easy to install, if you plan the location and
prepare the area properly.
1
Position the Thermolator as close to the process
machine as possible.
Alternate
locations
2
Make sure the installation area provides:
❒ ❒ A three-phase power source supplying the correct
current for your Thermolator model. Check the serial tag
on the side of the electrical enclosure for the required volt-
age, phase, frequency, full load amps, disconnect fuse size
and minimum wire connection size. Field wiring should be
completed by qualified personnel to the planned location
for the Thermolator. All electrical wiring should comply
with your region's electrical codes.
❒ ❒ A clean, well-ventilated environment.
The room temperature should not exceed 120° F (48° C)
with 95% non-condensing humidity and should not fall
below 32° F (0° C).
❒ ❒ Minimum clearance for safe operation and
maintenance. The diagram at right shows
minimum clearance for operation. You also
need enough clearance in the rear for
water hookups. For maintenance, you
should move the Thermolator to
provide at least 36 inches on any side
of the Thermolator.
❒ ❒ A source of water for cooling.
City, tower or chiller water may be used, as long as the
supply pressure is at least 25 psi and not more than 85 psi.
3
Install plumbing for process and cooling lines.
You will need two 1
process inlet and outlet and two 3/4-inch NPT male fit-
tings for the cooling inlet and outlet. Larger line sizes are
acceptable as long as they are reduced at the Thermolator
connections. Smaller line sizes are not recommended.
UGH015/0100
Process machine
1
-inch NPT male fittings for the
/
4
Thermolator TW-1 and TW-2
P
I
Thermolator
12 inches
(305 mm)
20 inches
(508 mm)
REPARING FOR
NSTALLATION
12 inches
(305 mm)
I
NSTALLATION
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtr1-diVtr2-di

Table of Contents