Specification Of Rework; Process Of Rework - Huawei MU709s-2 Hardware Manual

Hspa+ lga module
Hide thumbs Also See for MU709s-2:
Table of Contents

Advertisement

HUAWEI MU709s-2 HSPA+ LGA Module
Hardware Guide
Figure 6-5 Reflow profile
Table 6-2 Reflow parameters
Temperature Zone
Preheat zone
(40°C–150°C)
Soak zone
(150°C–200°C)
Reflow zone (> 217°C)
Cooling zone

6.9 Specification of Rework

6.9.1 Process of Rework

Issue 03 (2014-09-18)
Time
60s–120s
(t1–t2): 60s–120s
(t3–t4): 30s–90s
Cooling rate: 1°C/s ≤ Slope ≤ 4°C/s
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5BMechanical Specifications
Key Parameter
Heating rate: 0.5°C/s–2°C/s
Heating rate: < 1.0°C/s
Peak reflow temperature:
230°C–250°C
66