Repair work
58175005EN 01/2009 MPH-112
Version: 00
Lift the motor out of the base frame and simultaneously release the
clamping lever from the motor shaft.
When replacing the motor, proceed in the reverse order. Tighten the
motor lever screw (2) to a torque of 25 Nm.
IMPORTANT NOTE!
The resolver is mounted on the rear end of the motor. It cannot be
changed separately, only as a complete unit with the motor. The
resolver must be specially calibrated!