Hardware Design
4.1.5
RESET (Reset Input)
Signal Name
RESET
The Anybus CompactCom does not feature any internal reset regulation. To establish a reliable
interface, the host application is solely responsible for resetting the Anybus CompactCom when
the supply voltage is out of the specified range.
Power Up
Power
/RESET
Fig. 5
Powerup time limits are given in the table below:
Symbol
t
A
t
B
Restart
The reset pulse duration must be at least 10 µs in order for the Anybus CompactCom to properly
recognize a reset.
RESET
Fig. 6
Symbol
t
C
Anybus
®
CompactCom
™
B40 Modbus Serial User Manual
Pin Type
Pin
I
3
Power
On
3.3V
0V
t
A
V
IH
V
IL
Max.
Min.
Definition
-
-
Time until the power supply is stable after power-on; the duration depends
on the power supply design of the host application and is thus beyond the
scope of this document.
-
1 ms
Safety margin.
V
IH
V
IL
Max.
Min.
Definition
-
10 µs
Reset pulse width.
Description
Reset
Used to reset the module.
Power
Stable
t
B
t
C
18 (48)
t
t
t
SCM-1202-130 1.1 en-US
Need help?
Do you have a question about the Anybus CompactCom B40 Modbus Serial and is the answer not in the manual?
Questions and answers