11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step
1. Remove filter
a
Open the panel.
b
Loosen the clasp shown in the fig and
then pull the left filter and right filer
outwards to remove them.
2. Remove horizontal louver
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
76
Caution: discharge the refrigerant
completely before removal.
Procedure
Panel
Clasps
Left filter and right filer
Horizontal louver
Service Manual
Location of step motor
Axile bush