Gree GWH07AFA-K3NNA1A Service Manual page 97

Table of Contents

Advertisement

12. Remove magnet coil
Remove the screw fixing the magnet coil and then
remove the coil.
13. Remove valves and 4-way valve subassembly
Unsolder welding joint connecting the capillary,
the valve and the outlet pipe of condenser to
remove the capillary. Do not block the capillary
with welding slag during unsoldering .
Remove the 2 screws fixing the gas valve and
unsolder the welding point between the gas valve
and the air-return pipe to remove the gas valve.
(NOTE: Discharge the refrigerant completely
before unsoldering; when unsoldering, wrap the
gas valve with a wet cloth completely to avoid
damage to the valve caused by high temperature) .
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid
valve to the Y-type pipe to remove the liquid valve.
Unsolder the welding joint connecting the 4-way
valve, the compressor and the condenser to
remove the 4-way valve.
14. Remove compressor
Remove the foot nuts on the compressor and then
remove the compressor.
94
magnet coil
4- way valve
gas valv e
foot nuts
Service Manual
liquid valv e
compresso r
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents