3.8.4

Accessories / Options

No.
IR Receiver Kit
1
C4IRK01
Connecting
2
Cable
3
Wiring Cover
4
Cable Band
Installation Manual
5
6
Operation Manual
3.8.5

Installation

Perform the installation work for the IR receiver kit while the optional decorative panel is being attached to
1
the indoor unit.
When the IR receiver kit is attached after the decorative panel is attached to the indoor unit, turn OFF the
2
power supply of the indoor unit, and remove the decorative panel. Removing the decorative panel should
be performed according to the Installation Manual for the decorative panel or the Service Manual.
This IR receiver kit can be attached to any of four corners: 1 , 2 , 3 and 4 .
3
Determine the attachment location according to the purchaser's request.
NOTE:
The DIP switch setting for the IR receiver kit is
possible at more than one function. If the optional
function selection is required, perform work
according to the section, "Optional Functions"
before the IR receiver kit is attached to the
decorative panel.
Connect the accessory connecting cable to the terminal
4
block.
Open the electrical box cover of the indoor unit. Attach
the connecting cable to terminals A and B in the electrical
box. (There is no polarity with terminals A and B.)
TC-17005-rev.1
Accessory
Qty.
Remarks
1
With Connecting Cable
1
For Protection of
1
Connecting Cable
For Securing Wiring Cover
3
and Connecting Cable
1
1
Decorative Panel
1
3
Electrical Box
Connecting
Cable
OPTIONAL PARTS
-
-
-
2
4
Terminal Block for
Controller
Mark Band "B"
Mark Band "A"