19
environment, out of direct sunlight or any other heat source.
DO NOT force cool the pack in any way. Do not place in refrigerators
or freezers.
When the battery pack has cooled down it can again be used to
operate the Impact Driver, as long as the load or the conditions
causing the original excessive temperature has been corrected.
8.8 Low Voltage Cut Out
The battery pack used on this tool is fitted with a low voltage cut
out feature within the circuitry.
The low voltage cut out feature operates when the voltage drops
below a preset value. This feature automatically stops the Impact
Driver from operating (similar to that of the overload condition).
When this condition occurs you will need to either insert another
battery into the Impact Driver or recharge the existing battery.
The low voltage cut out feature has been added to maximise the
life of the battery cells in the battery. When this occurs, recharge
the battery pack by following the battery charging section in this
manual.
NOTE: Attempting to restart the tool without either recharging
the battery or installing another battery (with charge) will lead to
Impact Driver restarting and then stopping again, after only a few
seconds of operation.