Electrical Installation - BEA R2E-100 User Manual

Active infrared, request-to-exit sensor – dual relay output
Table of Contents

Advertisement

6 Mechanical Installation (cont.)
With the R2E disassembled, begin the installation procedure.
1.
Hold the R2E-100 up to the pre-determined location, which should be centered directly above the door handle (Picture 4 and Picture 5) and
attach using the 2 self-drilling screws that are included with the package. The housing has pre-drilled mounting holes at each end (Picture 6).
It may be necessary to drill a pilot hole (1/8" diameter) in the header for ease of screw installation.
Ensure the R2E-100 is mounted securely at each end.
4
Install R2E-100 with Lens Cover Facing Down Toward Door Handle
2.
If the R2E-100 is mounted directly to door header and cabling is to pass directly into header, drill a 3/8" hole next to the sensor's right end
cap to allow wire passage into header. The wire passage hole should be in a location that aligns with the cut-out in the housing.

7 Electrical Installation

Once the R2E-100 is attached to header, cabling, and wiring may be completed. Use the cable that is provided with a 14-pin connector.
For UL Listed installations, the R2E-100 should only be powered by a UL 294 Listed, power limited power supply, as well as connected to a UL
Listed electronic locking (EL) device or associated access control hardware.
For CAN/ULC-S319 Listed installations, the R2E-100 should only be powered by a ULC-S319 or ULC-S318 Listed, power limited or Class 2
power supply, as well as connected to a ULC-S319 Listed electronic locking (EL) device, card reader/keypad, and Door/REX switches.
Terminals and leads comply with CSA C22.1, Canadian Electrical Code, Part 1, Safety Standard for Electrical Installations.
©BEA
©BEA
| Original Instructions
| Original Instructions
75.5644.09 R2E-100 20181009
75.5644.09 R2E-100 20181009
5
Sensor Housing
Lens Cover
Door Handle
14-PIN CONNECTOR
WIRE COLOR
Red
12 to 24 VAC / DC +/- 10%
Black
12 to 24 VAC / DC +/- 10%
White/Black Stripe
Relay 1 Common
Green/Black Stripe
Relay 1 Normally Open
Yellow/Black Stripe
Relay 1 Normally Closed
White
Relay 2 Common
Green
Relay 2 Normally Open
Yellow
Relay 2 Normally Closed
Blue
DRY Card Reader Input
Blue/White Stripe
DRY Card Reader Input
Orange
DRY REX Input
Orange/White Stripe
DRY REX Input
Brown
DRY Door Position Switch Input
Brown/White Stripe
DRY Door Position Switch Input
NOTE: ALL CIRCUITS ARE POWER LIMITED, CLASS 2.
6
Ceiling
SIGNAL
Pre-drilled Mounting Holes
approx. 4 1/4" apart
Page 3 of 10
Page 3 of 10