MAINTENANCE _____________________________________________________________

NOTE: To avoid personal injury or damage to the Nitrogen Inflation System, permit only qualified personnel to
perform maintenance. When cleaning or replacing filter elements and automatic float drains,
disconnect airline from filters and turn Air Inlet valve to ON to allow air to drain from system.
When Air Inlet Pressure Gauge reads zero psi, you can service the filters.
See repair parts breakdown for replacement parts.
ALWAYS:
DAILY:
WEEKLY:
BI-YEARLY:
___________________________________________________________________________
OWNER'S RECORDS
___________________________________________________________________________
Keep Nitrogen Inflation System clean.
Check the automatic float drain on all filters for proper operation.
If the automatic float drain should become stuck open or inoperable, shut off the
air supply (see NOTE above). Remove the bottom cap from the bottom of the
filter. The drain can be cleaned in hot soapy water. DO NOT attempt to
disassemble the drain. If the drain is still inoperable after cleaning, it will have to
be replaced. When installing a new drain, make sure the o-ring is installed on the
bottom stem before screwing it into the bottom cap. Finger tighten only.
Clean the automatic float drain on both filters.
See above.
Clean particulate filter element and replace coalescing element.
Date Installed:
Serial number
_______________________
_______________________ Located on rear panel