INTENDED USE _____________________________________________________________
The Nitrogen Inflation System is a pneumatic device designed to generate deoxygenated air for the purpose of
inflating vehicle tires.

INSTALLATION INSTRUCTIONS _______________________________________________

1. Unpack and remove unit from shipping carton and pallet.
2. Inspect the unit for any visible damage.
3. Make sure the installation location is free from explosion or fire hazard and is a suitably ventilated;
otherwise, ventilate the area periodically during use of the equipment.
4. Make sure the plumbing from the air compressor to the Nitrogen Generator is made of an appropriately
rated copper, steel or aluminum and is at least 30 ft. in length.
5. Install on a solid level floor.
6. Anchoring the unit to the floor is not required but is recommended. Utilize the two holes in the base plate
to anchor the unit.
7. Connect the air supply line to the inlet on the back of the unit.
8. Connect the nitrogen supply line to the deoxygenated air outlet on either side of the unit.
9. Plug in the power cord to a 110/120 Volt outlet.
10. Slowly open ball valve at the inlet on the back of the unit.
NOTE:
The Nitrogen generator has a filter system that captures oil, water and other contaminants. However, if your
air supply system generates an excessive amount of water, etc., it may be desirable to install an air dryer.
The presence of any oil in the Nitrogen Membrane will void the

OPERATING INSTRUCTIONS _________________________________________________

Turning the Nitrogen Generator ON
1. Slowly rotate ball valve at the back of the unit, from the closed position to the open position.
2. Rotate switch on the front of the unit, from the "OFF" position to the "ON" position.
3. When the N
storage tank pressure reaches 160 psi, an automatic shut-off valve will stop the flow of air to
2
the nitrogen generator. This is done to prevent unnecessary use of the air compressor.
4. When the N
storage tank pressure drops to 145 psi, the automatic shut-off valve will open back up and
2
allow air flow thru the nitrogen generator.
5. To sample the nitrogen purity the nitrogen generator is producing, use the optional nitrogen analyzer and
check it at the N
NOTE: After the nitrogen line is pressurized or the N
Turning the Nitrogen Generator OFF
1. Slowly rotate ball valve at the back of the unit, from the open position to the closed position.
2. Rotate switch on the front of the unit, from the "ON" position to the "OFF" position.
PURITY ADJUSTMENT INSTRUCTIONS ______________________________
Your Nitrogen generator is equipped with a purity adjustment dial. Nitrogen purity is set to a minimum of
95%. To increase Nitrogen purity, rotate the purity adjustment dial clockwise. Maximum travel of the dial
will be approximately 360°.
NOTE: Increasing Nitrogen purity will decrease your Nitrogen flow.
To decrease Nitrogen purity, rotate the purity adjustment dial counter-clockwise. The line on the face of
the dial is the position indicator.
manufacturer's warranty.
sampling port (front panel) just as you would check a nitrogen filled tire.
2
NOTICE:
storage tank is filled, vehicle tires can then be inflated.
2
3