Installation Instruction; Select The Best Location - Panasonic CS-MZ5SKE Service Manual

Indoor unit
Hide thumbs Also See for CS-MZ5SKE:
Table of Contents

Advertisement

8. Installation Instruction

8.1

Select the Best Location

8.1.1
Indoor Unit
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
There should not be any heat source or steam
near the unit.
There should not be any obstacles blocking the air
circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit
shall be at least 2.5 m.
8.1.2
Indoor Unit Installation Diagram
Piping direction
(Front side)
Right
Right
Rear
Left
Right
Rear
Left
bottom
bottom
50 mm
or more
(Left and right are identical)
Insulation of piping connections
• Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to the wall
Remote control holder fi xing screws
Remote
control
3
Floor
It is advisable to avoid more than 2 blockage
directions. For better ventilation & multiple-outdoor
installation, please consult authorized dealer/
specialist.
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Respective outdoor unit installation procedure
shall refer to instruction manual provided in the
outdoor unit packaging.
21
Attention not to bend
up drain hose
Left
Installation parts you
should purchase ( )
Vinyl tape
6
Remote control holder
5
Installation plate 1
Bushing-Sleeve ( )
Sleeve ( )
Putty ( )
(Gum Type Sealer)
Bend the pipe as
closely on the wall
as possible, but be
careful that it doesn't
break.
Power supply cord ( )
Saddle ( )

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-mz5ske-m