3
4
5
6
Removing the cable harness in the upper arm
1
Product manual - IRB 8700
3HAC052853-001 Revision: F
Action
Make sure the o-ring is present.
Disconnect the motor cables.
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
© Copyright 2015-2018 ABB. All rights reserved.
4.5.6 Replacing the complete lower arm
Note
xx1200001070
xx1200001066
xx1200001067
Note
Continues on next page
4 Repair
Continued
371