Installation
3.1.4 Requirement 2 Side clearances—
(Measurements B, & C)
Where B, measured from the periphery of the
nearest burner to any vertical combustible sur-
face, or vertical combustible surface covered
with toughened glass or sheet metal, is less
than 200 mm, the surface shall be protected to
a height C of not less than 150 mm above the
cooktop for the full dimension (width or depth)
of the cooking surface area. Where the gas
cooking appliance is fitted with a 'splashback' ,
protection of the rear wall is not required.

3.2 Hose connection

Suitable for connection with a flexible hose
assembly. The flexible hose assembly must be
certified to AS/NZS 1869 class B or D, be of
appropriate internal diameter for the total gas
consumption, be kept as short as possible (not
exceeding 1200mm), must not be in contact
with the floor or any hot or sharp surfaces. The
hose assembly must not be subject to strain,
abrasion, kinking or deformation.
The supply connection point shall be accessible
with the appliance installed.
Built-In Hob / User Manual
3.2.1 Rooms with doors and/or
windows which open directly to the
outer environment
The doors and/or windows that open direct-
ly to the outer environment must have a total
ventilation opening of the dimensions spec-
ified in the table below which is based on the
total gas power of the appliance (total gas pow-
er consumption of the appliance is shown in the
technical specification table of this user manu-
al). If the doors and/or windows do not have a
total ventilation opening corresponding to the
total gas consumption of the appliance as spec-
ified in the table below, then there must defi-
nitely be an additional fixed ventilation opening
in the room to ensure that the total minimum
ventilation requirements for the total gas con-
sumption of the appliance is achieved. The
fixed ventilation opening can include openings
for existing airbricks, extraction hood ducting
opening dimension etc.
Total gas consump-
tion (MJ/h)
0-7
7-10
10-14
14-21
21-28
28-36
36-41
41-46
46-55
55-61
61-68
68-86
min. Ventilation
opening (cm2)
100
120
175
300
400
500
600
700
800
900
1000
1250