Fluke Datapaq TP3 User Manual page 51

For datapaq tracker systems with insight software
Table of Contents

Advertisement

process, oven/furnace/kiln, recipe or product file which will be applied to
the results. Click 'No Process' or 'Cancel' if you do not want to apply one.
A process file allows you to see the temperature profile in relation to the
oven/furnace/kiln zones as the profile appears on screen during the run. See
the Insight software for an introduction to process files: press function key F1, or
select Help > Contents from the menu bar, and click the section 'Process Files:
If you will normally not wish to apply a process file to the results, you can opt
not to have the Select Process dialog displayed immediately after a download
(from the menu bar, select Tools > Options > Process File); a process file may
9. The newly downloaded data then appears on screen numerically and
graphically. Save the data as a 'paqfile' (select File > Save or Save As).
The data from your profile run can now be displayed, printed and analyzed as
you wish; see Insight's online Help system for full details.
The means of proceeding to the next profile run after a logger download
depends on the contents of the logger memory, on whether the logger is in
multiple- or single-run mode (p. 45), and on whether you wish to change
the data-collection options.
• Logger in multiple-run mode:
○ If the logger memory contains nine or fewer profile runs (whether
or not they have been downloaded), data-recording for the next
run can be started by using the trigger selected in the
previous reset (e.g. start button or rising temperature; see p. 43);
the other previous data-collection options will then also be used.
○ If the logger memory contains 10 profile runs (whether or not they
have been downloaded), a new run cannot be started until the
logger memory has been emptied by resetting using Insight
(p. 41).
• Logger in single-run mode:
○ When starting the next profile run, the data held in the logger will be
deleted automatically (this is prevented if the data has not yet been
downloaded), so there is no need to reset the logger unless you wish
to change the data-collection parameters (see p. 47).
• For both multiple- and single-run modes:
○ To start a new run with different data-collection options, reset
the logger using Insight (p. 41).
DATAPAQ TP3
Oven, Recipe, Product'.
still be applied subsequently.
Using Insight Software
51

Hide quick links:

Advertisement

Table of Contents
loading