Clearances To Combustibles; Constructing The Appliance Enclosure - Outdoor Lifestyles ODPLAZA-L24S Installation Manual

Outdoor decorative gas appliance
Hide thumbs Also See for ODPLAZA-L24S:
Table of Contents

Advertisement

B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.2).
WARNING! Risk of Fire or Burns!
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
Appliance enclosure must be
made entirely of non-combustible
materials
E
D
Figure 3.2
Clearance to Combustibles
C. Constructing the Appliance Enclosure
Note: Take drainage into consideration when building
enclosure.
The appliance enclosure must be made entirely of non-
combustible materials such as metal studs and cement
board.
Minimum enclosure dimensions. See Figure 3.2.
The gas valves must be located on the outside of
enclosure or in an optional box and easily accessible.
Construction materials must be non-combustible if closer
than the minimum clearances shown in Figure 3.2.
8
Outdoor Lifestyles • ODPLAZA-L24S Installation Manual • 4079-311 • Rev B • 04/19
Provide adequate
Minimum Enclosure Dimensions and Clearances to Combustible Surface
ODPLAZA-L24S
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
A
D
A
B
C
in
17
17
45
mm
432
432
1143
C
B
Minimum clearances to
combustible walls,
floor and ceiling
D
E
8
8
203
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Odplaza-l24e

Table of Contents