7 Programming....................27 8 Connection scheme.................28 9 Dimensions....................32 10 Technical data..................33 Manufacturer reserves the right to make modifications in order to improve device operation. PXM Marek Żupnik sp.k. Podłęże 654 tel. +48 12 385 83 06 32-003 Podłęże mail: info@pxm.pl Rev.1-1 BDO register number 000005972 www.pxm.pl...
Description PX714 is an intelligent transistor dimmer with phase cutting where control is carried out on the falling edge (the so-called trailing edge dimming). The module controls four channels 200W each and has an built-in system of interference suppression, fuses and signal controls. The device has the DMX512 input, analogue inputs 0 –...
The device is closed in the standard housing designated for bar assembling. Safety conditions Dimmer PX741 is powered directly from standard 230V grid, what can cause electric shock when safety rules are not observed. Therefore it is necessary to observe the following: 1.
Page 5
5. To connect the devices to the dimmer, use only wires with a cross- section of not less than 0.75mm. 6. Dimmer can be installed in closed electrical switching stations only, with restricted access for people who does not handle proper qualifications 230V supplied devices maintenance.
NOTE!!! 1. The inappropriate connection of a protective wire creates the risk of electric shock. 2. The inappropriate connection of the neutral wire results in the faulty operation of a dimmer. 3. The dimmer can regulate exclusively the circuits (of capacity) of the resistive type or the capacitive one.
Designation of displayed messages address of the DMX device – the elementary position in the MENU setting parameters for all the channels simultaneously setting parameters for each channel separately blank screen – screen saving ON / OFF current temperature value total working time firmware version reset to factory default settings...
Page 8
setting the DMX address selection of the reaction mode to no DMX signal calibration of analogue inputs selection of one of four control function rise time in the push-button mode (from min to max) duration in the push-button mode (in function 4) falling time in the push-button mode minimum level which can be reached while dimming in function 2 scene: a control value for no DMX signal...
– enters the next MENU level and confirms changes made 5.2 Setting control modes The menu of the PX741 device allows to set the control mode of the device. Each of the device channels can be controlled with: •...
ENTER ENTER ENTER NEXT NEXT ENTER ENTER ENTER NEXT NEXT NEXT NEXT 5.2.1 DMX control DMX addressing In this menu, the DMX address can be set for individual channels individually or collectively for all the channels simultaneously and then the set address will be designated to the first channel and the next DMX addresses will be designated to next channels.
Page 11
Reaction to the lack of the DMX signal This function is used both to secure the installation against disappearance of the DMX signal and to achieve the desired value without the connection of an outer controller. On activating it, in case of no DMX signal, the module will realize the selected option individually.
Page 12
PREV PREV ENTER ENTER ENTER ENTER NEXT PREV ENTER ENTER NEXT NEXT NEXT NEXT PREV NEXT PREV ENTER ENTER ENTER ENTER NEXT NEXT PREV ENTER ENTER NEXT NEXT NEXT NEXT Setting time: InF – infinity time • SEC – seconds •...
5.2.2 Analogue control The control source from the analogue inputs can be set for each channel individually or collectively for all of them. Calibration should be carried out to ensure that the inputs work correctly. In order to do it, the maximum value should be set in the input and the CAL option should be selected, and then the message YES should be confirmed with the key “enter”.
Page 14
ENTER ENTER ENTER 2 x NEXT ENTER ENTER NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER 2 x NEXT NEXT ENTER ENTER NEXT NEXT NEXT NEXT NEXT Setting times: Function Available parameters InF – infinity time • uPt, dnt SEC –...
Page 15
Function diagrams for external button control: Function one output Falling time (parameter Rise time (parameter Time Pressing Releasing and holding the key the key down Function two output Falling time (parameter Rise time (parameter Time Pressing Short pressing Releasing and holding (<500 ms) the key the key down...
Page 16
Function three output Rise time Falling time (parameter (parameter Time Short pressing (<500 ms) Function four duration parameter hLd output Rise time Falling time (parameter (parameter Time Short pressing (<500 ms)
Each next short pressing of a key when the function realizes the parameter hLd causes that the time of the parameter is counted from 0 (it reset the time elapsed), prolonging the operation of the function at the same time. The value of this parameter is only taken into consideration in the fourth function.
ENTER ENTER NEXT NEXT ENTER ENTER ENTER NEXT NEXT NEXT ENTER NEXT NEXT Output NEXT NEXT 100% NEXT NEXT NEXT The curves: linear switched logarithmic exponential with index 2 exponential with index 3 5.4 Control range The minimum and maximum control values and the manner of behavior while reaching the limit values can be defined for each channel: the minimum level of connecting the output while rising •...
Page 19
the maximum level of control Hi • forcing the minimum status on the output PrE (when the channel is • not controlled) extending the output curve t the full control range Str • ENTER ENTER 2 x NEXT NEXT ENTER ENTER ENTER 2 x NEXT...
Page 20
b) Str = OFF, PrE = OFF Output 100% Loä c) Str = On, PrE = OFF Output 100% Loä d) Str = On, PrE = ON Output 100% Loä The curves: control level value on the output...
5.5 Screen saving The device was equipped with the possibility to switch off backlights for LED displays and signal diodes. The activated option bLc switches off the display after a period of one minute of inactivity (when the buttons are not used).
5.7 Working time Dimmer has been equipped with the ability to read the total working time of the Pwr device and the total time of actuation of the Lht channels. ENTER 4 x NEXT ENTER NEXT 5.8 Firmware version To verify the latest version of firmware, the option Fir should be selected and then the key “enter”...
5.9 Default settings To restore the factory default values, the dEF option should be selected and the key “enter” should be kept longer. Then, when the message YES appears, confirm with the key “enter”. It is also possible to exit from the level of this menu without the return to the factory default settings, in this case the key “esc”...
RDM – available parameters The PX741 supports the DMX-RDM protocol. DMX protocol allows only of a one-way data transmission, while its extension the RDM protocol can transmit information in two directions. This makes possibility of monitoring activities of the compatible devices. Thanks to RDM some available settings of compatible devices may be programmed using this protocol.
Page 25
Parameter name Description additional device description; It is possible to enter an additional DEVICE_LABEL * 0x0082 device description using up to 32 ASCII characters DMX_PERSONALITY * 0x00E0 DMX operational mode information on the selected SENSOR_DEFINITION 0x0200 temperature sensor SENSOR_VALUE 0x0201 information about sensors DEVICE_HOURS 0x0400 operating time counted CONTROL_HOURS...
Page 26
Parameter name Description minimum level of connecting the MINIMUM_LEVEL_INC. * 0x804A output while rising in range 0 – 100 minimum level of connecting MINIMUM_LEVEL_DEC. * 0x805A the output while falling in range 0 – 100 maximum level of control in range MAXIMUM_LEVEL* 0x8048 0 –...
Programming ENTER ENTER ENTER ENTER NEXT NEXT ENTER ENTER NEXT NEXT ENTER NEXT ENTER NEXT NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER ENTER NEXT NEXT NEXT NEXT ENTER ENTER NEXT NEXT...
Connection scheme a) DMX controller controller, e.g. PX333 230V POWER SUPPLY PROTECTIVE STRAND PHASE STRAND Type B circuit breaker NEUTRAL STRAND...
Page 29
b) Potentiometers control POTENTIOMETERS 0 - 10V IN 0 - 10V IN +10V OUT 230V POWER SUPPLY PROTECTIVE STRAND PHASE STRAND Type B circuit breaker NEUTRAL STRAND...
Page 30
c) 0 – 10V control 0 - 10V CONTROL SIGNAL SOURCES 0 - 10V IN 0 - 10V IN 0 - 10V IN 0 - 10V IN...
Page 31
d) Monostable buttons control MONOSTABLE BUTTONS 0 - 10V IN 0 - 10V IN 0 - 10V IN 0 - 10V IN +10V OUT 230V POWER SUPPLY PROTECTIVE STRAND PHASE STRAND Type B circuit breaker NEUTRAL STRAND...
10 Technical data type PX741 power supply 230V / 50Hz max. power consumption number of outputs voltage of outputs 230V / 50Hz load max. 200W / output 0 – 10V control inputs DMX512 monostable buttons power consumption inputs 0 – 10V...
Page 34
Podłęże, 09.04.2019 DECLARATION OF CONFORMITY PXM Marek Żupnik spółka komandytowa Podłęże 654, 32-003 Podłęże we declare that our product: Product name: Trailing Edge Dimmer Product code: PX741 meets the requirements of the following standards, as well as harmonised standards: PN-EN IEC 63000:2019-01...