2Diagnosis Of Modules, Sorted According To Ossd - Leuze lumiflex ASM1E Connecting And Operating Instructions

As-i safety monitor
Table of Contents

Advertisement

101
110
Table 11.2-1: Colour coding
Notice!
During proper protective operation, there are also modules which are not in the green
state. When searching for the cause of a shutdown, the module with the lowest index is
the most important. Others may just be subsequent effects (example: when the
emergency shutdown button is pressed, the start module and timer are also in the OFF
state).
By appropriately programming the functional component in the PLC, the user can be
guided to the primary cause of the error. Detailed knowledge of the configuration and
the function of the AS-i safety monitor are necessary for the interpretation of additional
information.
Since the module numbers may change if adjustments are made to the configuration, it
is advisable to use deactivated modules or NOP modules.
11.2.2 Diagnosis of modules, sorted according to OSSD
With the appropriate configuration setting, data calls (4) ... (B) return module diagno-
stic information sorted according to output circuit.
Notice!
Make sure that the correct diagnosis type is set for the AS-interface safety monitor in
the Information about monitor and bus window of the asimon configuration
software.
The values returned in calls (5) and (6) as well as (9) and (A) refer to the module index
in the configuration program and not to an AS-i address.
User modules have an index of 32 ... 79. Therefore 32 must be added to the read
value in order to obtain the same module number as that shown in asimon.
Always execute data calls (4) ... (7) and (8) ... (B) together in sequence for each
module.
Sorted module diagnosis, output circuit 1
If answer to data call (1) = 10X1:
Data call / Value
(4) / 1011
Number of modu-
les not green, out-
put circuit 1
red,
The error lock is active, release by means of one of the fol-
flashing
lowing actions:
Acknowledge with the service button
Power OFF/ON
AS-i bus OFF/ON
grey,
No communication with the AS-i slave
off
Answer
Meaning
D3 ... D0
0XXX
XXX = 0:
XXX = 1 ... 6:
XXX = 7:
ASM1, ASM1E
no modules, answers to data calls
(5) ... (7) not relevant
number of modules in output circuit 1
number of modules is > 6 in output
circuit 1
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asm1

Table of Contents