TLE5014
GMR-Based Angle Sensor
Examples
Table 23
Writing of EEPROM page 0x006) (cont'd)
Type
Command
write
0x4671
write
0x4681
write
0x4671
Sensor stays in this mode with SICI interface enabled. To return to normal interface, sensor reset is necessary
(can be done by power-down or sending the reset command 0x0001 to address 0x01:
write
0x4011
User's Manual
Data
Comment
newDATA
Writes newDATA to register 0x67,
corresponds to intended new content of EEPROM
address 0x006E
0x03FF
Prepare EEPROM programing
0x0009
Program EEPROM with automatic verification
0x0001
Reset command, sensor restarts with default interface
51
Rev. 1.0
2019-03-12