GMR-Based Angle Sensor
Initial Calibration
In case the look-up table is not used, make sure that the default values are written in the corresponding
addresses. The default value is the ideal angle value at the defined position, e.g. address 0x00B0: 0°, 0x00B2:
11.25°, ...
The chip is delivered from Infineon with the default values already written to the look-up table.
An example how to use the look-up table can be found in
Chapter
9.3.
8.3

Customer ID

The chip provides a storage of 112 bit for customer data. This data can be written to the EEPROM page 0x00F
(see
Table
10). The first 32 bits (address 0x00F2 and 0x00F4) are also transmitted during operation via the
short serial message feature of the SENT and SPC protocol in case it is enabled. Please note that the customer
data are not CRC protected.