Properties of the SEPARIX system

The SEPARIX system is a warning system that, depending on the version, is able to monitor
both the thickness of the oil or light liquid layer in a light liquid separator as well as the level
of this fluid. The system consists of the following components:
– Interface sensor SEPARIX-C L Plus
– High-level sensor SEPARIX-T L Plus
– SEPARIX-Control CT measuring transducer
The measuring transducer serves as power supply and signal processing of the sensors.
The sensors transmit a signal to the connected measuring transducer whenever the oil /
light liquid layer exceeds a defined thickness (interface sensor) or whenever the liquid level
in the separator rises above an impermissible threshold (high-level sensor). The measuring
transducer then generates alarms so that appropriate measures can be taken to stop con-
taminants from being discharged into the sewage system.
Faults and alarms are signalled visually by LEDs and audibly by a buzzer. The measuring
transducer also supports the connection of external alarm transmitters.
2

Safety instructions

SEPARIX serves for monitoring the light liquid layer and/or the liquid level in light liquid
separators. Use the system exclusively for this purpose. The manufacturer accepts no liabil-
ity for any form of damage resulting from improper use.
The interface sensors, high-level sensors and measuring transducers have been developed,
manufactured and tested in accordance with the latest good engineering practices and
generally accepted safety standards. Nevertheless, hazards may arise from their use. For
this reason, the following safety instructions must be observed:
Do not change or modify the system or add any equipment without the prior con-
sent of the manufacturer.
The installation and maintenance of the measuring transducer and the sensors must
be carried out only by expert personnel. Specialised knowledge must be acquired
by regular training.
All installation and maintenance work, with the exception of functional testing, must
be carried out with the power disconnected.
Installers and service technicians must comply with all applicable safety regulations.
This also applies to any local safety and accident prevention regulations which are
not stated in this user guide.
Page 1/37